This group includes messages for the IOA (infrastructure) product.
Explanation: There is insufficient memory to run the IOADUL utility.
The utility terminates with a return code of 12.
Corrective Action: Increase the REGION size and rerun the utility.
Explanation: The IOADUL utility detected an error while opening a sequential file to which it is to unload the data.
The utility terminates with a return code of 16.
Corrective Action: Check the IOA Log and the system job log for more information. Correct the error and rerun the job. If error persists, contact BMC Customer Support.
Explanation: The IOADUL utility detected an error when opening the IOA Access Method file referenced by the DADBS DD statement.
The utility terminates with a return code of 20.
Corrective Action: Check the IOA Log and the system job log for more information. Correct the error and rerun the job. If error persists, contact BMC Customer Support.
Explanation: This information message indicates that the IOADUL utility started. The IOADUL utility unloads the records of an IOA Access Method file to a sequential file.
Corrective Action: No action is required.
Explanation: This information message indicates that the IOADUL utility terminated with a return code of num.
The IOADUL utility terminates.
Corrective Action: Check the IOA Log and the system job log for more information. Correct the error and rerun the job. If error persists, contact BMC Customer Support.
Explanation: The IOADUL utility detected an error while loading the IOAPARM member.
The IOADUL utility terminates with a return code of 4.
Corrective Action: Check the IOA Log and the system job log for more information. Correct the error, and rerun the job. If the error persists, contact BMC Customer Support.
Explanation: The IOADUL utility detected an error while reading the IOA Access Method file.
The IOADUL utility terminates with a return code of 24.
Corrective Action: Check the IOA Log and the system job log for more information. Correct the error, and rerun the job. If the error persists, contact BMC Customer Support.
Explanation: Invalid input parameters were specified when running the IOADUL utility.
The IOADUL utility ends with a return code of 28.
Corrective Action: Rerun the IOADUL utility using valid input parameters. For information on the valid parameters, see the IOADUL utility in the INCONTROL for z/OS Utilities Guide.
Explanation: No input parameters were specified for the IOADUL utility.
The IOADUL utility ends with a return code of 32.
Corrective Action: Rerun the IOADUL utility using valid input parameters. See the IOADUL utility in the INCONTROL for z/OS Utilities Guide for valid parameters.
Explanation: This information message displays the number of records copied from a database to a sequential file by the IOADUL utility.
Corrective Action: No action is required.
Parent Topic |