Messages DMI600 through DMI6xx

This group includes messages for the Control-O product.

DMI670E ACB CONTROL BLOCK IS NOT VALID

Explanation: The alternate subsystem encountered an ACB control block that does not have a valid identifier.

The Control-O subsystem terminates the connection between the alternate subsystem and the Control-O subsystem.

Corrective Action: Contact BMC Customer Support.

DMI671E SSI ROUTINE SUBSYSTEM IS INACTIVE

Explanation: The CTODMI alternate subsystem module failed to invoke the Control-O subsystem. Because the Control-O subsystem is not active, there is no connection between the alternate subsystem and the Control-O subsystem.

Communication between the alternate subsystem and the Control-O subsystem fails.

Corrective Action: Reactivate Control-O in order to reestablish communication.

DMI672E SSI ROUTINE DETECTED AN ERROR

Explanation: Control-O encountered an internal error (a return code of 16) while attempting to process the SSI request to transmit information from the alternate subsystem to the Control-O subsystem.

The information is not transmitted.

Corrective Action: Contact BMC Customer Support.

DMI673E SSI ROUTINE RETURNED AN UNDEFINED RETURN CODE

Explanation: Control-O encountered an internal error (a return code of 20) while processing an SSI request. The alternate subsystem was trying to transmit data to the Control-O subsystem.

The data is not transmitted.

Corrective Action: Contact BMC Customer Support.

DMI674E CTO SSCT POINTER NOT SET - SSI ROUTINE INVOCATION BYPASSED

Explanation: The pointer to the Control-O subsystem SSCT was not set. The initialization process normally sets the pointer to the Control-O subsystem SSCT.

Communication between the Control-O subsystem and the alternate subsystem terminates.

Corrective Action: Contact BMC Customer Support.

Parent Topic

DMI messages