Previous Topic

Next Topic

Book Contents

Book Index

Messages DIV900 through DIV9xx

This group includes messages for the Control-M/Analyzer product.

DIV961I CONTROL-M/ANALYZER UTILITY CTBDBVIG STARTED

Explanation: This information message indicates the normal start of the CTBDBVIG Control-M/Analyzer database integrity-checking utility.

Corrective Action: No action is required.

DIV962S INSUFFICIENT STORAGE TO RUN UTILITY CTBDBVIG

Explanation: The CTBDBVIG Control-M/Analyzer utility requires more storage to perform an integrity check on a Control-M/ Data file.

The utility stops executing with a condition code of 12.

Corrective Action: Increase the REGION size, and rerun the job.

DIV963S CONTROL-M/ANALYZER DATA FILE OPEN FAILED

Explanation: The CTBDBVIG Control-M/Analyzer utility could not open the Control-M/Analyzer Data file for which integrity checking was requested. Possible causes are:

The utility stops executing with a condition code of 20.

Corrective Action: Correct the JCL, and rerun the job. If the error persists, notify your INCONTROL administrator.

DIV965I INTEGRITY ERRORS DETECTED. TO CORRECT, SPECIFY "ACT=W"

Explanation: This information message indicates that the CTBDBVIG Control-M/Analyzer utility detected integrity errors while checking the Control-M/Analyzer database.

The utility stops executing with a condition code of 32.

Corrective Action: Notify your INCONTROL administrator before rerunning the utility.

DIV966S ERROR UPDATING CONTROL-M/ANALYZER DATA FILES

Explanation: The CTBDBVIG Control-M/Analyzer utility failed due to an internal error.

The utility stops executing with a nonzero condition code.

Corrective Action: Notify your INCONTROL administrator.

DIV967S BAD RBA ENCOUNTERED WHILE SCANNING MODELS FILE AT BLOCK= blk RECORD= rec

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an invalid RBA while checking the rec record.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV968S INCONSISTENT NAMING AT BLOCK= blk RECORD= rec IN MODELS FILE

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an error while checking the rec record.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV969S BAD RBA ENCOUNTERED WHILE SCANNING VARIABLES AT BLOCK= blk RECORD= rec

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an error while checking the rec record in the modules file.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV96AS MULTIPLE REFERENCES TO BASE AT BLOCK= blk RECORD= rec

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an error while checking the rec record.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV96BS MULTIPLE REFERENCES TO VARIABLE AT BLOCK= blk RECORD= rec

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an error while checking the rec record.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV96CS UNREFERENCED VARIABLE AT BLOCK= blk RECORD= rec

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an unreferenced variable while checking the rec record.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV96DI CONTROL-M/ANALYZER UTILITY CTBDVIG ENDED

Explanation: This information message indicates the normal termination of the CTBDBVIG Control-M/Analyzer utility, the Control-M/Analyzer database integrity-checking utility.

Corrective Action: No action is required.

DIV96ES INCONSISTENT NAMING AT BLOCK= blk RECORD= rec IN VARIABLES FILE

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an error while checking the record identified in the message.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV96FI VARIABLES DATA BASE INTEGRITY HAS BEEN VALIDATED

Explanation: This information message indicates the database integrity validation process has been completed by the CTBDBVIG Control-M/Analyzer utility.

Corrective Action: No action is required.

DIV970S UNREFERENCED BASE AT BLOCK= blk RECORD= rec

Explanation: The CTBDBVIG Control-M/Analyzer utility detected an error while checking the record indicated in the message.

The utility continues executing.

Corrective Action: Notify your INCONTROL administrator.

DIV971S ERROR OPENING SYSPRINT

Explanation: This information message indicates that the CTBDBIV Control-M/Analyzer utility failed to open the print file referenced by the SYSPRINT DD statement.

Possible causes are:

The utility stops executing with a condition code of 08.

Corrective Action: Correct the JCL and rerun the job.

Parent Topic

DIV messages