Previous Topic

Next Topic

Book Contents

Book Index

Messages DFL100 through DFL1xx

This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.

DFL185E ERROR WHILE READING SYSOUT FOR MEMBER memName JOBID jobId

Explanation: Reading of sysout for the specified job failed. The tape pull list performs JCL checking by submitting the jobs with TYPRUN set to SCAN and reading the results from spool. A typical cause is a manual purge at the job from spool.

Corrective Action: Check earlier error messages that describe the type of error.

DFL187W UNRESOLVED BACKWARD REFERENCE FOR DDNAME ddName

Explanation: Backward reference was not resolved for the ddName DD statement.

The information for this DD statement is ignored by the utility.

Corrective Action: Check the next error message to identify the job name and step name where the error was detected.

DFL188W UNIT NAME NOT SPECIFIED FOR NEW DATASET IN DDNAME ddName

Explanation: No UNIT specification was found for the NEW data set allocated to the specified DD name.

The information for this DD statement is ignored by utility.

Corrective Action: Look for the next error message to identify the job name and step name where the error was detected.

DFL189I MEMBER memName PGMSTEP pgmStep PROCSTEP procStep

Explanation: The information message identifies the location of the errors described by the previous message.

Corrective Action: No action is required.

DFL190W NOT CATLGD2 MAY BE ENCOUNTERED FOR DDNAME ddName

Explanation: The data set allocated to the specified DD statement is already cataloged. It is possible that the data set is not currently cataloged, but will be created and cataloged before the execution of the specified job.

Corrective Action: Look for the next error message to identify the job name and step name where the error was detected.

Parent Topic

DFL messages