This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.
Explanation: This information message indicates that the logical connection between the Control-M Application Server and Control-M/Enterprise Manager (Control-M/EM) Workstation Gateway is temporarily suspended because the Active Jobs file is currently being formatted.
The workstation database is not up-to-date, and no requests issued by the Control-M/EM GUI will be handled, until the format of the Active Jobs file is completed.
Corrective Action: No action is required.
Explanation: This information message indicates that the logical connection between the Control-M Application Server and Control-M/Enterprise Manager (Control-M/EM) Workstation Gateway has resumed because the process of formatting the Active Jobs file has finished.
The workstation database may now request synchronization, and other requests issued by the Control-M/EM GUI will now be handled.
Corrective Action: No action is required.
Explanation: An abend occurred when the Active Jobs file (AJF) was last formatted. The New Day process did not finish OK. ECSGATE cannot work with the AJF, because the AJF might be corrupted.
The Control-M Application Server shuts down.
Corrective Action: Inform your INCONTROL administrator.
Explanation: The data set pointed to by the "DARESF" OR "DACNDF" DD statement is not your IOA Synchronization file. This error message is issued by the CTWDET Control-M Application Server program, and is due to one of the following:
The Control-M Application Server shuts down.
Corrective Action: Correct the JCL for the Control-M Application Server and restart it.
Explanation: The Control-M Application Server detected that a job on the Active Jobs file does not have all related continuation records.
In this message, add is the Relative Byte address of the problematic job.
The problematic job is ignored, meaning that it is not downloaded to Control-M/Enterprise Manager. The Application Server continues to work, handling other jobs.
Corrective Action: Have your system programmer call BMC Customer Support.
Explanation: This information message indicates that the Control-M Active Jobs File (AJF) is currently being formatted.
The Control-M Application Server holds updates. After formatting is finished, it executes a full download to the Control-M/Enterprise Manager.
Corrective Action: No action is required.
Explanation: The Control-M Application Server sent database updates to the Control-M/Enterprise Manager (Control-M/EM) Workstation Gateway, but did not receive confirmation for them in time. This error message is issued by the CTWDET Control-M Application Server program, and is due to one of the following:
Corrective Action: Check if the workstation is hanging and if there are any error messages at the workstation which indicate the cause of the problem. If the workstation is not hanging, there must be some performance bottleneck in the system. Try to determine whether this bottleneck is at the workstation side, in the communication media, or at the mainframe.
Explanation: The Control-M Application Server has received an out of order confirmation of a database update.
This error message is issued by the CTWDET Control-M Application Server program. The Mainframe Gateway expects to receive confirmations for database updates in increasing order, but a confirmation with a sequence number of rcv_num has been received, when a confirmation with a sequence number of at least exp_num was expected.
The Control-M Application Server continues executing.
Corrective Action: Have your INCONTROL administrator contact BMC Customer Support.
Explanation: The Control-M Application Server detected that during its last sleeping period it missed some events.
This message is issued by the CTWDET Control-M Application Server program. The Mainframe Gateway has detected that the run number of the jobName job in the Control-M Active Jobs file has changed by more than one during the Mainframe Gateway’s last sleeping period. This means that run numbers run_num1 to run_num2 of the job have not been captured by the Mainframe Gateway.
Corrective Action: Consider decreasing the SLEEPINT parameter in the relevant APSERVER statement in the ECAPARM member.
Explanation: The detector program detected an internal error. This error message is issued by the Control-M Application Server, and is due to reasons not in user control.
The Control-M Application Server shuts down.
Corrective Action: Have your INCONTROL administrator contact BMC Customer Support.
Explanation: This information message indicates that a download will be executed, and the reason.
Possible causes of this message are:
Possible values for rsnText are:
The Control-M Application Server requests and will execute a full download to the Control-M/Enterprise Manager.
Corrective Action: No action is required.