Previous Topic

Next Topic

Book Contents

Book Index

Messages CVIG00 through CVIGxx

This group includes messages for the Control-V product.

CVIGC0S INTERNAL ERROR IN CONVERSION PROGRAM

Explanation: An internal error occurred when converting index records from VSAM into IOA Access Method records. The error occurred during the transfer of internal parameters.

The database conversion utility terminates with an error. The VSAM file is not converted into an IOA Access Method file.

Corrective Action: Supply BMC Customer Support with the sysout of the conversion job.

CVIGC1E CLOSE OF INDEX FILE fileName FAILED

Explanation: An internal error occurred when converting index records from VSAM into IOA Access Method records. The conversion utility was unable to close an index file.

The database conversion utility terminates with an error. The VSAM file is not converted into an IOA Access Method file.

Corrective Action: Supply BMC Customer Support with the sysout of the conversion job and the name of the index file identified in the message.

CVIGC5S INTERNAL ERROR - FREEMAIN ERROR. RC = rc

Explanation: The FREEMAIN macro failed to free space that is controlled by GETMAIN.

The executing program may stop. The system response varies with the environment that issued the message.

Corrective Action: Contact BMC Customer Support.

CVIGC6E INSUFFICIENT MEMORY - GETMAIN ERROR. RC = rc

Explanation: There is not enough memory to convert a VSAM file into an IOA Access Method file.

The database conversion utility terminates with an error. The VSAM file is not converted into an IOA Access Method file.

Corrective Action: Increase the region size and rerun the utility.

Parent Topic

CVI messages