CTWI00I DOWNLOAD OF IOA DATA BASE STARTED

Explanation: This information message is issued by the Enterprise Controlstation Download utility to indicate that downloading of the IOA and Control-M database is currently in progress.

Corrective Action: No action is required.

CTWI01I DOWNLOAD OF IOA DATA BASE ENDED SUCCESSFULLY

Explanation: Information message issued by the Enterprise Controlstation Download utility, indicating that the download of the IOA and Control-M database has ended successfully.

Corrective Action: No action is required.

CTWI02E RESOURCE resourceName CONTAINS NULL, INTERNAL CODE code

Explanation: A resource containing nulls in its name was encountered during download or database update. A null is not valid in the name of a quantitative or control resource.

The Control-M Application Server terminates with a condition code of 08.

Corrective Action: Report the occurrence to BMC Customer Support.

CTWI03E OPEN OF ENTERPRISE/CS INFO DOWNLOAD FILE FAILED. DDNAME "DWNINFO"

Explanation: The Enterprise Controlstation Download utility could not open the Download Info file (DD statement DWNINFO).

Possible causes are:

The Enterprise Controlstation Download utility stops executing.

Corrective Action: Correct the download JCL procedure or the JCL for the download job and rerun the download job.

CTWI04E OPEN OF ENTERPRISE/CS JOBS DOWNLOAD FILE FAILED. DDNAME "DWNJOBS"

Explanation: The Enterprise Controlstation Download utility could not open the Download Jobs file (DD statement DWNJOBS).

Possible causes are:

The Enterprise Controlstation Download utility stops executing.

Corrective Action: Correct the download JCL procedure or the JCL for the download job and rerun the download job.

CTWI06E INSUFFICIENT STORAGE FOR THE ENTERPRISE/CS DOWNLOAD UTILITY

Explanation: The Enterprise Controlstation Download utility requires more storage in order to execute.

The Enterprise Controlstation Download utility stops executing.

Corrective Action: Increase the REGION size and rerun the download job.

CTWI07E DOWNLOAD INTERNAL ERROR TYPE type

Explanation: An internal error occurred during execution of the Enterprise Controlstation Download utility.

The Enterprise Controlstation Download utility stops executing.

Corrective Action: Have your INCONTROL administrator contact BMC Customer Support.

CTWI08E OPEN OF ENTERPRISE/CS APPLICATION-GROUP DEFINITION FILE FAILED. DDNAME "DAGROUP"

Explanation: The Control-M Application Server or Download utility is unable to open the Application-Group Definition file (DD statement DAGROUP). This may be due to one of the following:

The Control-M Application Server or Download utility continues executing, but without processing the applications.

Corrective Action: Correct the Control-M Application Server JCL procedure and restart the Control-M Application Server, or correct the download JCL procedure or the JCL for the download job and rerun the download job.

CTWI09E MAXIMUM APPLICATIONS IN ENTERPRISE/CS APPLICATION-GROUP DEFINITION FILE EXCEEDED. DDNAME "DAGROUP"

Explanation: The Control-M Application Server or Download utility is unable to process all the applications in the Application-Group Definition file (the DAGROUP DD statement). Too many applications were defined in the Application-Group Definition file.

The Control-M Application Server or Download utility continues executing, but processes only some of the applications.

Corrective Action: Check the Application-Group Definition file, and if it is correct, contact BMC Customer Support.

CTWI10E MAXIMUM GROUPS IN ENTERPRISE/CS APPLICATION-GROUP DEFINITION FILE EXCEEDED. DDNAME "DAGROUP"

Explanation: The Control-M Application Server or Download utility is unable to process all the groups in the Application-Group Definition file (the DAGROUP DD statement). Too many groups were defined in the Application-Group Definition file.

The Control-M Application Server or Download utility continues executing, but processes only some of the groups.

Corrective Action: Check the Application-Group Definition file, and if it is correct, contact BMC Customer Support.

CTWI11E INVALID STATEMENT IN ENTERPRISE/CS APPLICATION-GROUP DEFINITION FILE. DDNAME "DAGROUP"

Explanation: The Control-M Application Server or Download utility is unable to process a statement in the Application-Group Definition file (the DAGROUP DD statement). An invalid statement appeared in the Application-Group Definition file.

The Control-M Application Server or Download utility continues executing, but skips processing of the invalid instruction.

Corrective Action: Correct the syntax in the Application-Group Definition file, and restart the Control-M Application Server or rerun the Enterprise Controlstation Download utility.

CTWI14E OPEN OF ENTERPRISE/CS CONTROL RESOURCES DOWNLOAD FILE FAILED. DDNAME "DWNCNTRL"

Explanation: The Enterprise Controlstation Download utility could not open the Download Control Resources file (the DWNCNTRL DD statement). Possible causes are:

The Enterprise Controlstation Download utility stops executing.

Corrective Action: Correct the download JCL procedure or the JCL for the download job and rerun the download job.

CTWI15E OPEN OF ENTERPRISE/CS QUANTITATIVE RESOURCES DOWNLOAD FILE FAILED. DDNAME "DWNQUANT"

Explanation: The Enterprise Controlstation Download utility is unable to open the Download Quantitative Resources file (the DWNQUANT DD statement).

Possible causes are:

The Enterprise Controlstation Download utility stops executing.

Corrective Action: Correct the download JCL procedure or the JCL for the download job and rerun the download job.

CTWI50I BUILDING OF ECS COMMUNICATION DATASET STARTED

Explanation: This information message indicates that the Enterprise Controlstation Communication Dataset formatting utility started allocating and formatting the Enterprise Controlstation Communication Dataset file.

Corrective Action: No action is required.

CTWI51I BUILDING OF ECS COMMUNICATION DATASET ENDED

Explanation: This information message indicates that the Enterprise Controlstation Communication Dataset formatting utility completed allocation and formatting of the Enterprise Controlstation Communication Dataset file normally.

Corrective Action: No action is required.

CTWI52E BUILDING OF ECS COMMUNICATION DATASET FAILED

Explanation: The Enterprise Controlstation Communication Dataset formatting utility failed.

The utility fails.

Corrective Action: Look for an earlier error message that describes the type of error.

CTWI53E OPEN OF DDNAME DAM2G FAILED

Explanation: The Enterprise Controlstation Communication Dataset formatting utility failed to open the Enterprise Controlstation Communication Dataset file that is allocated to DD statement DAM2G. Possible causes are:

The utility stops executing with a condition code of 08.

Corrective Action: Correct the JCL and rerun the job.

CTWI54E I/O ERROR OCCURRED WHILE BUILDING THE ECS COMMUNICATION DATASET

Explanation: An I/O error occurred in the Enterprise Controlstation Communication Dataset formatting utility while formatting the Enterprise Controlstation Communication Dataset file.

The utility stops executing with a condition code of 08.

Corrective Action: Correct the file DCB parameters, and rerun the job. If necessary, contact BMC Customer Support.

CTWI55E THE SIZE OF SHOUT TO ECS COMMUNICATION DATASET IS NOT SET CORRECTLY

Explanation: An invalid value was specified on installation for the M2GSIZE parameter. The utility stops executing with a condition code of 08.

Corrective Action: Specify a valid value for the M2GSIZE parameter, and rerun the file creation process, as follows:

If this message was issued in a customized installation, do the following to set a valid value for the M2GSIZE parameter:

  1. Open the IOA Installation and Customization Engine (ICE).
  2. On the ICE Main Menu, select Installation.
  3. On the IOA Installation screen, select Customized installation.
  4. Set the Product ID to IOA, type 2 (INSTALL IOA) in the OPTION field, and press Enter.
  5. Select Major Step 21 (Install Control-M Application Server), Minor Step 2 (Shout to Control-M/EM Parameters).
  6. Change the value of the M2GSIZE parameter.

If this message was issued in a Default installation, save and exit the installation, change the value using the ICE Main Menu Customization option, run the job, and then return to the Default installation.

If this message was issued in a cloning installation, you first need to finish the cloning installation and then change the value using the ICE Main Menu Customization option. For more information, see the “Customizing INCONTROL products” section of the INCONTROL for z/OS Installation Guide.

CTWI56W SHOUT TO ECS COMMUNICATION DATASET OVERFLOWED. SOME MESSAGES MAY BE LOST

Explanation: The number of Shout messages written to the Enterprise Controlstation Communication Dataset file exceeded the available space. The Enterprise Controlstation Communication Dataset file contains a fixed number of blocks determined by the M2GSIZE parameter. Each block may contain one Shout message. Each time a Shout message is read from the file, a block is freed. Messages are being written to the file faster than they are read.

Old messages in the file are overwritten by newer Shout messages.

Corrective Action: If this condition occurs regularly, increase the size of the Enterprise Controlstation Communication Dataset file.

Parent Topic