Messages CTT700 through CTT7xx

This group includes messages for the Control-M/Tape product.

CTT700I text

Explanation: This information message displays one of the following:

Corrective Action: No action is required.

CTT701S INCLUDE/EXCLUDE STATEMENT ERROR. FUNCTION=func, RC=rc. EXECUTION WILL TERMINATE

Explanation: A syntax error occurred in an INCLUDE/EXCLUDE statement.

The variables in this message are:

Valid values for func and rc, and their explanations, are displayed in the following table:

Function

Return Code

Explanation

INIT

08

Insufficient memory

 

36

Internal error

BUILD

08

Too many INCLUDE/EXCLUDE statements

 

12

The statement is not of the INCLUDE/EXCLUDE type.

 

16

One of the following problems occurred:

  • The parameter specified exceeds 44 characters.
  • No parameter was specified.
  • The keyword in invalid. It is not in the dictionary.
  • The parameter specified is not allowed (not in the dictionary).

 

20

The > (greater than) or < (less than) relation is not allowed in the specified format.

 

24

The date value is not numeric.

 

28

The date value is neither 6 nor 8 digits.

 

32

Internal error

 

36

The value is neither numeric nor hexadecimal.

SELECT

8

An INCLUDE/EXCLUDE block is empty.

 

32

Internal error

 

40

The field being used for comparison contains an invalid numeric value.

Execution stops.

Corrective Action: Correct the statement and rerun the utility.

CTT702S STATEMENT PARSING ERROR. REASON=rsn. EXECUTION WILL TERMINATE

Explanation: A parsing error occurred in one or more control statements. The reason code (rsn) in the message text indicates the type of error that occurred, as shown in the following table:

Utility

rsn

Explanation

All Utilities

4

No keywords were found

 

8

Continuation statement is missing

 

12

Operation code not found. No keywords parsed.

 

16

No keywords found in the parsed record, or a mandatory keyword was not found.

 

20

Redundant data in a parsed record.

 

24

Internal error. Missing parameter name in command definition.

 

28

More than 255 characters to parse.

 

48

More than 31 input parameter lines.

CTTDLD

32

Range is invalid. FROM volser is higher than TO volser or volser range does not provide logical sequencing.

 

52

Continuation statement missing.

CTTIDB

28

Invalid MODE parameter or more than 255 characters to parse.

 

32

Invalid relation in statement.

CTTMER

50

OPCODE not found.

 

54

Relation in statement is missing or invalid.

 

58

Parameter is too long.

 

62

DBGLEVEL is not numeric.

 

70

Too many MERGE statements.

 

74

MERGE statement is missing.

 

78

Invalid MODE parameter.

CTTSPL

50

OPCODE not found.

 

54

Relation in statement is missing or invalid.

 

58

Parameter is too long.

 

62

DBGLEVEL is not numeric.

 

70

Too many SPLIT statements.

 

74

SPLIT statement is missing.

 

78

Invalid MODE parameter.

 

82

Invalid FUNCTION parameter.

Execution is terminated.

Corrective Action: Correct the control statement and rerun the utility.

CTT703I recd_type RECORDS action = num

Explanation: This message is generated to provide additional information from a Control-M/Tape utility.

Message variables are:

Corrective Action: No action is required.

CTT704I CONTROL-M/TAPE UTILITY utility STARTED

Explanation: This information message indicates that a Control-M/Tape utility has started execution.

Corrective Action: No action is required.

CTT705I CONTROL-M/TAPE UTILITY utility ENDED RC=rc

Explanation: This information message indicates that a Control-M/Tape utility has ended with return code rc.

Corrective Action: No action is required.

CTT707S PARAMETERS parm1 AND parm2 ARE MUTUALLY EXCLUSIVE

Explanation: The specified parameters passed to the utility are mutually exclusive and therefore cannot be specified together.

The utility does not start processing.

Corrective Action: Specify either one of the parameters, but not both.

CTT708S UNRECOGNIZED POSITIONAL PARAMETER parm

Explanation: The specified positional parameter passed to the utility is unrecognized.

The utility does not start processing.

Corrective Action: Refer to the utility description in the INCONTROL for z/OS Utilities Guide for information regarding parameters which can be passed to the utility.

CTT709S POSITIONAL PARAMETER parm APPEARED MORE THAN ONCE

Explanation: The positional parameter was specified more than once as input to the utility.

The utility does not start processing.

Corrective Action: Specify this parameter only once. Refer to the utility description in the INCONTROL for z/OS Utilities Guide for more information regarding parameters that can be passed to the utility.

CTT710S STATEMENT VALIDATION ERROR IN KEYWORD keyName, EXECUTION WILL TERMINATE

Explanation: Validation error in scanning parameters of the specified keyword.

Execution is terminated.

Corrective Action: Correct the keyword parameters and rerun the utility.

CTT711I num RECORDS COPIED

Explanation: This information message indicates that the CTTACP utility copied the specified number of records.

Corrective Action: No action is required.

CTT712I num STATEMENTS READ FROM SYSIN

Explanation: This information message specifies how many control statements SYSIN has read.

Corrective Action: No action is required.

CTT713I format TYPE RECORDS - PROCESSED = n1, SELECTED = n2

Explanation: This information message indicates that the Stacking Database was built as shown.

The variables in this message are:

Corrective Action: No action is required.

CTT714I TOTAL OF n1 RECORDS READ n2 DUPLICATE RECORDS WERE DROPPED

Explanation: This information message indicates that the Stacking Database was built as shown.

The variables in this message are:

Corrective Action: No action is required.

CTT715S ROUTINE routineName FAILED. RC=rc

Explanation: A severe internal error occurred in the specified routine.

The variables in this message are:

Execution is terminated.

Corrective Action: Check accompanying messages.

CTT716S {RETENTION | VAULTING} PROCEDURE ENDED WITH ERRORS

Explanation: Due to logical errors on the Media Database (MDB), a retention or a vaulting procedure ended with errors. This message follows other messages that indicate the exact nature of the problem.

The procedure terminates with errors.

Corrective Action: Check the accompanying error messages, and proceed accordingly.

CTT717E INVALID EXPIRATION DATA. RECORD KEY=key

Explanation: The data set or volume record contains invalid expiration information.

The CTTRTM (CTTVTM) utility skips the bad record and continues executing.

Corrective Action: Contact your database administrator.

CTT718I ANOTHER CTT UTILITY IS USING THE MDB. TRY AGAIN LATER

Explanation: This information message indicates that the requested utility requires, but cannot access, the Media Database, which is in use by another utility. Simultaneous access to the Media Database by these utilities might corrupt the data. Therefore, only one of the utilities at a time can access the database.

Corrective Action: Run the requested Control-M/Tape utility after the previous utility has ended.

CTT719E {POOL | RULE | VAULT} DEFINITION LOAD FAILED

Explanation: Control-M/Tape cannot load the Pool, Rule, or Vault definition into memory, for one of the following reasons:

Execution stops.

Corrective Action: Examine the job log and the IOA log for messages relating to this error, and take appropriate corrective action.

CTT720E VAULT vault NOT FOUND. VOLUME=vol

Explanation: Control-M/Tape did not find the vault name vault in the vault definition.

Control-M/Tape moves the volume to the vault, and continues processing.

Corrective Action: Add the vault to the vault definition using the Vault Definition screen.

CTT721E INVALID LOCATION loc FOR VOLUME vol

Explanation: Volume was marked as vaulted, but the current vault name (location) is not in the volume vault list.

The CTTVTM utility skips the volume, and continues executing.

Corrective Action: Contact your INCONTROL administrator.

CTT722E INTERNAL ERROR IN DATA. RECORD=key

Explanation: Control-M/Tape detected one of the following errors in the indicated record:

This message is issued by the Online Facility, by the CTTRTM utility, or by the CTTVTM utility.

Execution continues with another record from the Media Database.

Corrective Action: Notify your database administrator.

CTT723E CHAIN ERROR ON VOLUME vol

Explanation: A Control-M/Tape utility detected a multivolume chain error. Possible causes are:

This message is accompanied by other messages that provide additional information about the problematic record.

Corrective Action: No action is required.

CTT724I VOLSER=volser ; RBA=rba ; {FIRST | NEXT | PREV} = volser ; {LABEL = lbl| DSN = dsn }

Explanation: This information message provides information about a volser that caused an error. It accompanies error messages issued by other utilities.

Corrective Action: No action is required.

CTT725W CHAIN INCOMPLETE BECAUSE OF INCLUDE/EXCLUDE SELECTION OR CHAIN ERROR

Explanation: The CTTVTM utility detected an incomplete multivolume chain. Possible causes are:

This message is accompanied by message CTT724I, which provides additional information (VOLSER and RBA) about the problematic/missing record.

Corrective Action: No action is required.

CTT726E VOLUME vol NOT IN SEQUENCE (seqNumber)

Explanation: A Control-M/Tape utility detected that the seq_no sequence number in the vol volume is out of sequence in the volume chain. This problem generally relates to the conversion process.

Corrective Action: No action is required.

CTT727E CTTRPT FAILED. RC=rc, STATEMENT={FIELDS | SORTBY | BREAK}, PARM=parmName, ROW=row_id

Explanation: The CTTRPT utility, invoked directly or called internally by another utility, failed due to an invalid value in the parmName parameter.

In this message, row_id is the ROWID specified in a BREAK or SORTBY statement. The type of error is indicated by the return code (rc), as follows:

rc

Explanation

08

Missing DD statements or open error occurred.

12

Control card error.

16

Operation code not found.

20

Invalid operation code.

24

Syntax error in REPORT, FIELDS or SORTBY statement.

28

Field name specified in FIELDS or SORTBY list is undefined.

32

Same parameter specified more than once.

36

Field name exceeds maximum length.

40

Invalid relation specified (must always be an equal sign).

44

Report NAME is undefined.

48

BRK not specified for the preceding field in the SORTBY list.

52

FIELDS statement not specified.

56

Total of all field lengths requested in the FIELDS statement exceeds the line size.

60

Continuation card expected but not received.

64

Invalid numeric value.

68

Option in the FIELDS or SORTBY statement already specified.

72

ROWID specified in the BREAK or SORTBY statement.

76

EDIT parameter in the ATTR statement is invalid for the specified FIELDS.

80

EDIT mask is not valid.

84

Specified number not in permitted range.

For example, the end column of a MARGIN statement exceeds the LINESIZE, or a column in a FIELDS statement is outside the margins of the report.

88

Column option (/C) not specified in the preceding field.

92

One of the following has occurred:

  • No column is specified in the current FIELDS statement.
  • The specified column in a FIELDS statement is inconsistent with the column specified in another FIELDS statement

108

Insufficient memory.

112

All fields specified for the primary and secondary line have the BRK attribute

200

Fields in the FIELDS or SORTBY statements do not fit the PATH parameter of the EXTRACT statement.

The utility is stopped.

Corrective Action: Depending on the return code, check and correct the appropriate parameters or DD statements.

CTT728I CONTROL-M/TAPE UTILITY util IS RUNNING. MDB UPDATES DELAYED

Explanation: This information message is issued upon the start of an IDB utility, which checks and analyzes Media Database integrity.

The message is highlighted and unrollable until the utility has finished accessing the Media Database.

Corrective Action: No action is required.

CTT729E CONTINUATION RECORD NOT FOUND FOR VOLUME volser

Explanation: Control-M/Tape tried to expire a volume that has continuation records (DTR records) that are not in the Media Database. This message is issued by either the Online Facility or by the CTTRTM utility.

Corrective Action: Notify your database administrator.

CTT730E MAXIMUM CAPACITY EXCEEDED FOR MEDIA type

Explanation: The value specified in the CAPACITY USD field exceeded the maximum capacity value defined in CTTPARM for the type media type. An attempt was made to update the CAPACITY USD field on a volume record through screen TI.

Corrective Action: Decrease the value in the CAPACITY USD field.

CTT731E LAST LABEL NUMBER CANNOT BE BELOW NUMBER OF ACTIVE DATASETS

Explanation: The value in the LAST LABEL field is invalid.

This message is issued in one of the following circumstances:

In the Control-M/Tape database:

Corrective Action: Adjust the value in the LAST LABEL field to a number equal to the highest label number of all the active data sets on the volume.

CTT732E VOLUME vol IS ACTIVE AND HAS NO DATASETS

Explanation: A utility detected a volume data record which is marked as active, but the volume has no associated data set.

The utility continues processing.

Corrective Action: Contact your database administrator for assistance.

CTT733E NUMBER OF ACTIVE DATASETS CANNOT BE BELOW NUMBER OF EXISTING DATASETS

Explanation: The value in the FILES field cannot be less than the actual number of data sets which reside on the selected volume. An attempt was made to update the FILES field on a volume record through Screen TI.

Corrective Action: Increase the value in the FILES field so that it is not less than the actual number of data sets on the volume.

CTT734E DATASET num DOES NOT EXIST ON THE VOLUME

Explanation: The user tried to update the DATASET NUM field within Vaulting Information on a volume record, but a data set with label number num was not found on the selected volume.

Corrective Action: Correct the value in the DATASET NUM field.

CTT735E MAXIMUM PREFIX NAME LENGTH EXCEEDED

Explanation: An attempt was made to update the DSNAME PREF LTH field in Vaulting Information on a volume record with a value greater than 44. The maximum value for the DSNAME PREF LTH field is 44.

Corrective Action: Decrease the value in the DSNAME PREF LTH field to a value not greater than 44.

CTT736E DUPLICATE {VOLUME | DATASET}: rkey

Explanation: The CTTIDB utility detected two or more data records with the same key (rkey).

The utility continues processing.

Corrective Action: Contact your database administrator for assistance.

CTT737E MAXIMUM NUMBER OF MEDIA BLOCKS EXCEEDED. VAULT vault

Explanation: The CTTVTM utility detected more than 10 different media types defined for the specified vault. No more than 10 media types can be defined for a vault.

Only the first 10 media types are considered by the CTTVTM utility. The utility continues processing.

Corrective Action: Decrease the number of media types in the vault definition through screen TV.

CTT738E VAULT vault NOT DEFINED

Explanation: The Media Database contains information about slot assignment in the specified vault, but that vault is not defined through screen TV.

The CTTVTM utility continues processing.

Corrective Action: If the vault should be defined, define it through screen TV. Otherwise, ignore the message.

CTT739E MEDIA mediaName NOT DEFINED FOR VAULT vault

Explanation: The mediaName media type is not defined for the vault through screen TV.

The CTTVTM utility continues processing.

Corrective Action: Define the media type for the vault from screen TV.

CTT740W VOLUME vol SKIPPED. RANGE INVALID

Explanation: The CTTDLD utility, with TYPERUN set to CONVERT, detected a volume with VOLSER set to vol that was not defined in a RANGE statement.

The specified volume is not converted.

Corrective Action: Correct the definition of the RANGE statement.

CTT742W DUPLICATE DATASETS ON SAME VOLUME - VOL=SER=volser LABEL=lbl. DATASET NOT ADDED

Explanation: The CTTDLD utility, with TYPERUN set to CONVERT, detected a volume (volser) with multiple data sets residing on the same label.

Only one data set is added to the Media Database (MDB).

Corrective Action: List the data sets of the volume and define the data sets on it manually.

CTT743W VOLUME vol IS NOT A SCRATCH VOLUME. VOLUME NOT DELETED

Explanation: The CTTDLD utility, with TYPERUN set to DELETE, detected a non-scratch volume to be deleted from the Media Database (MDB).

The volume is not deleted.

Corrective Action: Check the status of the volume and verify why it is not scratch.

CTT744S RETENTION TYPE NOT RECOGNIZED. TYPE=type RMFKEY=key

Explanation: During conversion from CA-TLMS RMF (Retention Master File), an invalid retention type was detected in the input.

The volumes that will contain the data set indicated in the RMFKEY are assigned a permanent retention type.

Corrective Action: Check and correct the data set retention type in the Control-M/Tape rule definition.

CTT745S CONDITIONS IN VAULT PATTERN CONTROL STATEMENT EXCEEDED. DSN=dsName

Explanation: The conversion program encountered too many vault control statements in the definition file being converted.

The extra conditions are ignored.

Corrective Action: Check your CA-1 vault management definition for valid conditions.

CTT746W control NOT SUPPORTED. DSN=dsName

Explanation: The control value specified for the data set name is not relevant for Control-M/Tape.

The control statement is ignored. Conversion continues.

Corrective Action: No action is required.

CTT747S INSTALLATION NOT IN UCC-1

Explanation: The conversion routine that converts CA-1 VMS or VPDS to Control-M/Tape rules discovered that the input parameters were set for a non UCC-1 installation. The CTTCVMS program checks the EXPDTYPE parameter in the CTTPARM, and issues this message if the parameter is not set to CA1.

Rule conversion is stopped.

Corrective Action: Change the EXPDTYPE in the CTTPARM to CA1, if you are converting from CA-1 to Control-M/Tape.

CTT748W EXPIRATION DATE: date NOT SUPPORTED. VOL=vol

Explanation: The CTTDLD utility, with TYPERUN set to CONVERT, detected an unrecognizable expiration date.

The specified volume with this expiration date is assigned a permanent expiration date.

Corrective Action: Check volume retention type and date. Redefine it in the Control-M/Tape Inquire/Update Entry Panel if permanent status is incorrect.

CTT749E INVALID COMBINATION OF FIRST,LAST AND RENAME FIELDS

Explanation: An invalid combination of FIRST, LAST and RENAME values was used in a RANGE statement. The length of the string specified for RENAME must not exceed the length of the corresponding part of the FIRST and LAST prefixes. The FIRST and LAST prefixes must be identical.

The CTTDLD utility is terminated.

Corrective Action: Correct the RANGE statement and rerun the CTTDLD utility.

Parent Topic

CTT messages