This group includes messages for the Control-O product.
Explanation: This information message indicates that the Control-O subsystem subsys is now active and as a result the IMS Automated Operator Interface (AOI) messages can now be processed.
Corrective Action: No action is required.
Explanation: IMS Automated Operator Interface (AOI) messages cannot be processed because Control-O subsystem subsys is not active.
No segments of the current AOI message are processed.
Corrective Action: Activate Control-O.
Explanation: An internal error occurred while processing an IMS Automated Operator Interface (AOI) message.
No segments of the current AOI message are processed.
Corrective Action: Contact BMC Customer Support.
Explanation: An internal error occurred while processing an IMS Automated Operator Interface (AOI) message.
No segments of the current AOI message are processed.
Corrective Action: Contact BMC Customer Support.
Explanation: The Control-O IMS Interface detected an internal abend, where systemCode is the system abend code, and userCode is the user abend code. This is the header message for messages CTOI07I, CTOI08I, CTOI09I, and CTOI10I which provide information about the abend.
A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.
Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.
Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. The message details the PSW at time of abend, and the entry points of the related Control-O modules. This message follows message CTOI06E and precedes messages CTOI08I, CTOI09I, and CTOI10I.
A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.
Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.
Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. This message is a header for messages CTOI09I and CTOI10I which detail the contents of the registers at time of abend. This message follows messages CTOI06E and CTOI07I.
A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.
Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.
Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. The header for this message is message CTOI08I. This message details the contents of registers 0 - 7 at time of abend. (It is followed by message CTOI10I, which details the contents of registers 8 - 15.)
A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.
Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.
Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. This message follows messages CTOI08I and CTOI09I. This message details the contents of registers 8 - 15 at time of abend.
A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.
Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.
Explanation: A FREEMAIN request by the Control-O IMS Interface failed. The probable cause is an internal error.
Corrective Action: Contact BMC Customer Support.
Explanation: This information message indicates that initialization of the DFSAOE00 Control-O IMS module is complete for the IMS DB/DC, DCCTL, or DBCTL address space.
The DFSAOE00 Control-O IMS interface module is ready for requests.
Corrective Action: No action is required.
Explanation: This warning message indicates that a /CTO START command was issued to start or restart the Control-O IMS interface, but the interface is already active.
The START request is rejected.
Corrective Action: No action is required.
Explanation: This information message indicates that the Control-O IMS interface stopped in response to a /CTO STOP command.
Corrective Action: To reactivate the interface, issue the command /CTO START.
Explanation: This information message indicates that a /CTO TRACE=ON command to start the Control-O / IMS trace messages was issued and accepted.
TRACE messages may be issued by the DFSAOE00 Control-O IMS interface module.
Corrective Action: To stop the trace, issue the command /CTO TRACE=OFF
Explanation: This is an echo message. It shows the text of a /CTO command as received from IMS by the DFSAOE00 interface module.
Corrective Action: No action is required.
Explanation: An invalid /CTO command was issued to Control-O IMS interface. The text of the command appears in the previously issued message CTOI18I.
The command is rejected.
Corrective Action: Correct the command and reissue it.
Explanation: The command /CTO START was issued to restart the Control-O / IMS interface, but the interface rejects the command because /CTO CANCEL has already been issued, and this prevents the interface from reactivating.
The request is rejected.
Corrective Action: To restart the Control-O IMS interface, stop IMS, then restart it again.
Explanation: This information indicates that the Control-O IMS interface stopped in response to a /CTO CANCEL command. The interface between IMS and Control-O using IOA subsystem subsys cannot be reactivated for this IMS region.
Corrective Action: To restart the Control-O IMS interface, stop IMS and restart it again.
Parent Topic |