Previous Topic

Next Topic

Book Contents

Book Index

Messages CTOI00 through CTOIxx

This group includes messages for the Control-O product.

CTOI00I CTO SUBSYSTEM subsys NOW ACTIVE. IMS AOI MESSAGE PROCESSED

Explanation: This information message indicates that the Control-O subsystem subsys is now active and as a result the IMS Automated Operator Interface (AOI) messages can now be processed.

Corrective Action: No action is required.

CTOI02E CTO SUBSYSTEM subsys INACTIVE. IMS AOI MESSAGES NOT PROCESSED

Explanation: IMS Automated Operator Interface (AOI) messages cannot be processed because Control-O subsystem subsys is not active.

No segments of the current AOI message are processed.

Corrective Action: Activate Control-O.

CTOI03E CTO SUBSYSTEM subsys DETECTED AN ERROR WHILE PROCESSING AN IMS AOI MESSAGE

Explanation: An internal error occurred while processing an IMS Automated Operator Interface (AOI) message.

No segments of the current AOI message are processed.

Corrective Action: Contact BMC Customer Support.

CTOI04E CTO SUBSYSTEM subsys RETURNED AN INVALID RC FOR AN IMS AOI MESSAGE

Explanation: An internal error occurred while processing an IMS Automated Operator Interface (AOI) message.

No segments of the current AOI message are processed.

Corrective Action: Contact BMC Customer Support.

CTOI06E INTERNAL ABEND=(systemCode,userCode)

Explanation: The Control-O IMS Interface detected an internal abend, where systemCode is the system abend code, and userCode is the user abend code. This is the header message for messages CTOI07I, CTOI08I, CTOI09I, and CTOI10I which provide information about the abend.

A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.

Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.

CTOI07I PSW AT TIME OF ABEND=psw DFSAOUE0 EP=add1 CTOEXEC EP=add2

Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. The message details the PSW at time of abend, and the entry points of the related Control-O modules. This message follows message CTOI06E and precedes messages CTOI08I, CTOI09I, and CTOI10I.

A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.

Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.

CTOI08I REGISTERS AT TIME OF ABEND (R0 - R15):

Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. This message is a header for messages CTOI09I and CTOI10I which detail the contents of the registers at time of abend. This message follows messages CTOI06E and CTOI07I.

A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.

Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.

CTOI09I register0 register1 ... register7

Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. The header for this message is message CTOI08I. This message details the contents of registers 0 - 7 at time of abend. (It is followed by message CTOI10I, which details the contents of registers 8 - 15.)

A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.

Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.

CTOI10I register8 register9 ... register15

Explanation: This information message indicates that the Control-O IMS Interface detected an internal abend. This message follows messages CTOI08I and CTOI09I. This message details the contents of registers 8 - 15 at time of abend.

A dump of the address space is produced on the first abend intercepted by the Control-O IMS Interface. Processing of the current IMS Automated Operator Interface (AOI) message is stopped. Subsequent AOI messages are processed.

Corrective Action: Check the dump and the related messages. If the problem is related to IMS customization, or to storage violations due to user transactions, correct the problem. Otherwise, contact BMC Customer Support.

CTOI11E FREEMAIN OF ADDRESS add FAILED

Explanation: A FREEMAIN request by the Control-O IMS Interface failed. The probable cause is an internal error.

Corrective Action: Contact BMC Customer Support.

CTOI12I CONTROL-O IMS/ ims_region INTERFACE INITIALIZATION COMPLETED FOR SUBSYSTEM subsys IMS

Explanation: This information message indicates that initialization of the DFSAOE00 Control-O IMS module is complete for the IMS DB/DC, DCCTL, or DBCTL address space.

The DFSAOE00 Control-O IMS interface module is ready for requests.

Corrective Action: No action is required.

CTOI13W START REQUEST INVALID. INTERFACE ALREADY STARTED

Explanation: This warning message indicates that a /CTO START command was issued to start or restart the Control-O IMS interface, but the interface is already active.

The START request is rejected.

Corrective Action: No action is required.

CTOI15I CONTROL-O IMS/ims_region INTERFACE STOPPED FOR SUBSYSTEM subsys IMS

Explanation: This information message indicates that the Control-O IMS interface stopped in response to a /CTO STOP command.

Corrective Action: To reactivate the interface, issue the command /CTO START.

CTOI17I TRACE REQUEST ACCEPTED

Explanation: This information message indicates that a /CTO TRACE=ON command to start the Control-O / IMS trace messages was issued and accepted.

TRACE messages may be issued by the DFSAOE00 Control-O IMS interface module.

Corrective Action: To stop the trace, issue the command /CTO TRACE=OFF

CTOI18I text

Explanation: This is an echo message. It shows the text of a /CTO command as received from IMS by the DFSAOE00 interface module.

Corrective Action: No action is required.

CTOI19E INVALID COMMAND - COMMAND IGNORED

Explanation: An invalid /CTO command was issued to Control-O IMS interface. The text of the command appears in the previously issued message CTOI18I.

The command is rejected.

Corrective Action: Correct the command and reissue it.

CTOI20E START REQUEST INVALID. INTERFACE WAS PREVIOUSLY CANCELED

Explanation: The command /CTO START was issued to restart the Control-O / IMS interface, but the interface rejects the command because /CTO CANCEL has already been issued, and this prevents the interface from reactivating.

The request is rejected.

Corrective Action: To restart the Control-O IMS interface, stop IMS, then restart it again.

CTOI21I CONTROL-O IMS/ ims_region INTERFACE CANCELED FOR SUBSYSTEM subsys

Explanation: This information indicates that the Control-O IMS interface stopped in response to a /CTO CANCEL command. The interface between IMS and Control-O using IOA subsystem subsys cannot be reactivated for this IMS region.

Corrective Action: To restart the Control-O IMS interface, stop IMS and restart it again.

Parent Topic

CTO messages