This group includes messages for the Control-O product.
Explanation: Control-O changes the NUMCONS parameter, in the CTOPARM member, to zero.
The Control-O startup process continues.
Corrective Action: If the CTOPARM member is only used for Control-O set NUMCONS=0 in the CTOPARM member.
Explanation: Invalid format of Control- x Installation DAYTIME parameter. DAYTIME is the start time of the Control-M work day in your installation. Valid formats are +hhmm or -hhmm.
For more details see the section that describes installation parameters in the chapter for the appropriate products in the INCONTROL for z/OS Installation Guide.
The requested function terminates.
Corrective Action: Call your system programmer to correct the DAYTIME parameter in the CT xPARM member.
Explanation: The opening of a print file failed.
Possible causes are:
The program stops executing.
Corrective Action: Correct the JCL and submit again.
Explanation: During the startup of the Control-O monitor, an error is encountered in the Control-O installation parameters. The nature of the error is detailed in an accompanying message or messages.
The Control-O monitor terminates.
Corrective Action: Contact your INCONTROL administrator.
Explanation: During the startup of the Control-O monitor, an error occurred during Control-O initialization. The nature of the error is detailed in an accompanying message or messages.
The Control-O monitor terminates.
Corrective Action: Contact your INCONTROL administrator.
Explanation: During the startup of the Control-O monitor, the values of the JCMDSSN and the SSNAME parameters were found to be identical.
The JCMDSSN parameter identifies the JES2 command suppression subsystem name, and is in the CTOPARM member.
The SSNAME parameter identifies the IOA subsystem, and is in the IOAPARM parameter.
The value of the JCMDSSN parameter is replaced with blanks. Monitor startup continues.
Corrective Action: Contact your INCONTROL administrator.
Explanation: The Control-O component could not be initialized because the getmain in length getmain_length failed.
The specified monitor will shut down.
Corrective Action: Increase the REGION size of the specified monitor.
Explanation: During Control-O or CMEM monitor initialization, it was discovered that the existing subsys subsystem is already activated for the version version of the monitor. The active monitor is shut down.
Corrective Action: Determine which monitor (the active one or the newly started) should use the subsystem and act accordingly.
Explanation:The RQC# parameter in the CTOPARM member was changed, and a new Control-O/CMEM was started over a running one. The new RQC# value is not used.
xxxx - the old RQC# from the previous Control-O execution
Corrective Action: Shut down Control-O/CMEM.
After the started task ends, start a new Control-O/CMEM. Verify that the new RQC# is being used by examining the started task job log.
Parent Topic |