Previous Topic

Next Topic

Book Contents

Book Index

Messages CTM100 through CTM1xx

This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.

CTM100I CONTROL-M MONITOR STARTED

Explanation: This information message is a general message issued when the Control-M monitor is started.

Corrective Action: No action is required.

CTM101I NEWCONLIST COMMAND ACCEPTED. SUB SYSTEM(S) WILL BE NOTIFIED

Explanation: This information message appears after the operator issued a NEWCONLIST modify command to Control-M.

The Control-M monitor will notify all the console subsystems on all the computers of the required change.

Corrective Action: No action is required.

CTM101S LCT EXCEEDED MAXIMUM NUMBER OF ENTRIES (10000)

Explanation: An attempt was made to add an entry to the Local Command Table (LCT), an internal program table, but it already contains the maximum number of allowable entries.

Control-M Extended MCS tracking is stopped.

Corrective Action: Check the SPY289E message, which always accompanies this message, and proceed accordingly.

CTM102E CONTROL-M MONITOR NOT APF-AUTHORIZED

Explanation: The Control-M monitor is not APF-authorized. The CTMRUN module is not in an APF-authorized library, or does not have the AC attribute set to 1.

The Control-M monitor terminates with a return code of 8.

Corrective Action: Add the library name in which CTMRUN resides to the IEAAPF00 member in SYS1.PARMLIB.

CTM102S JNF EXCEEDED MAXIMUM NUMBER OF ENTRIES (10000)

Explanation: An attempt was made to add an entry to the Job Not Found Table (JNF), an internal program table, but it already contains the maximum number of allowable entries.

Control-M Extended MCS tracking is stopped.

Corrective Action: Check the SPY289E message, which always accompanies this message, and proceed accordingly.

CTM103E INVALID MODIFY PARAMETER. VALID PARAMETERS ARE:

Explanation: An erroneous parameter was passed to the Control-M monitor by an operator modify command (F). A list of valid modify parameters is displayed on the console after this message.

The modify command is rejected.

Corrective Action: Enter a correct modify parameter.

CTM104S BLDL/ATTACH CTMMRUN FAILED FOR TASK taskName

Explanation: Initialization of the taskName Control-M monitor internal task failed.

Possible causes are:

The exact reason (system code) can be found on the computer log.

Control-M monitor shuts down.

Corrective Action: Call your system programmer for assistance. If necessary, increase the Control-M monitor REGION size.

CTM105S UNRECOVERABLE ERROR ENCOUNTERED

Explanation: An unrecoverable error occurred in the operation of the Control-M monitor.

The IOA Log contains a previous message concerning the error.

The Control-M monitor may:

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, prepare the Control-M monitor full output and contact BMC Customer Support.

CTM106S SUBTASK subtaskName HAS ABENDED

Explanation: The subtaskName Control-M monitor internal subtask has abended.

Control-M monitor shuts down with the 0006 user abend. A dump of the abending task will be included in the output.

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, prepare the Control-M monitor full output and contact BMC Customer Support.

CTM107I SHUT DOWN UPON REQUEST FROM OPERATOR

Explanation: This information message is issued when the Control-M monitor is shut down upon request from the operator.

Control-M monitor shuts down.

Corrective Action: No action is required.

CTM108S INITIALIZATION ROUTINE FAILED. RC= rc

Explanation: Highlighted, unrollable message.

Error encountered when initializing the Control-M monitor.

The exact cause of the error is indicated by the return code (rc).

The Control-M monitor shuts down.

Corrective Action: If the return code (rc) is 4, verify that the JES subsystem name as defined in IEFSSNxx is either JES2 or JES3, and that the JESTYPS parameter in the IOAPARM member is either JES2 or JES3.

If the return code is 8, certain load modules are missing from the IOA LOAD library. Restore the original LOAD library.

If the return code is 24, the IOADEST table (the dynamic destination table for group Shout messages) is missing from the IOA PARM library.

CTM109I THE NUMBER OF INTERVALS TO WAIT FOR THE CONTROL-M DAILY IS SET TO numberIntervals

Explanation: This information message indicates that after a Control-M monitor issues message CTM113I, it is waiting for the displayed number of Control-M sleeping intervals for the New Day procedure to start executing. If the New Day procedure does not start executing, message CTML03W is issued, followed by message CTML06W.

Corrective Action: No action is required.

CTM111I JOURNAL COMMAND ACCEPTED: cmd

Explanation: This information message indicates that a JOURNAL=ENABLE or JOURNAL=DISABLE modify command was accepted. The command is echoed (as cmd) in the message.

Corrective Action: No action is required.

CTM112E SMFID smfid IS NOT DEFINED IN CONTROL-M INSTALLATION PARAMETERS

Explanation: The Control-O or CMEM subsystem initialization routine is running under a CPU that was not defined in the IOACPRM member.

Possible causes are:

Control-O or CMEM monitor shuts down.

Corrective Action: Do the following:

  1. Check that the SMFID of the computer in which Control-O or CMEM is being initialized is defined in the list of SMFIDs in the IOACPRM member.
  2. If the IOACPRM definition appears correct, check the SMFID defined in SYS1.PARMLIB.
  3. In a multi-CPU computer, issue from the console the MVS command D M=CPU to receive a listing of all CPU serial numbers, and compare them with the PARMLIB definition.

CTM112I fileName SUPPORT NOT ACTIVATED

Explanation: This information message indicates that History/Journal support is not set to Y in the CTMPARM member.

This message is generated in response to a HISTALOC/JOURNAL=ENABLE or HISTALOC/JOURNAL=DISABLE modify command. This command could not be processed because History/Journaling is not enabled.

Corrective Action: Set HIST/JRNL to Y in the CTMPARM member.

CTM113I CONTROL-M MONITOR monName NEW DAY PROCESSING STARTED

Explanation: Highlighted, unrollable message.

This information message indicates that the monName Control-M monitor has begun performing a number of housekeeping tasks prior to submitting the New Day procedure.

Control-M suspends processing at the time specified in CTMPARM to allow the New Day procedure to run.

The Control-M monitor remains suspended until the New Day procedure is successfully completed. At the successful completion of the New Day procedure, the monitor resumes normal execution.

Corrective Action: No action is required.

CTM113W CONTROL-M MONITOR SHUTTING DOWN FOR A NEW DAY

Explanation: Highlighted, unrollable message.

See RUN113W.

Corrective Action: No action is required.

CTM114E JOB HANDLED AT TIME OF ABEND: ID= id MEMBER= memName USER-ID= userId

Explanation: A subtask abended.

As a result of the subtask abend, the RUN106S message is issued. This message follows RUN106S with additional information. The ID (id), member name (memName), and user ID (userId) displayed in the message are from the Master Index file (MIT) that was handled by the subtask when it abended.

Corrective Action: No action is required.

CTM116S OPEN OF ACTIVE JOBS FILE FAILED - DDNAME "DACKPT"

Explanation: Highlighted, unrollable message.

Open of Control-M Active Jobs file failed (the DACKPT DD statement). Possible causes are:

Control-M monitor shuts down.

Corrective Action: Correct the JCL for the Control-M monitor.

CTM117S ACTIVE JOBS FILE IS BEING FORMATTED NOW

Explanation: Highlighted, unrollable message.

Control-M monitor was started while the Active Jobs file was being formatted.

The New Day procedure did not finish formatting the file, either because it is still working, or because it abended. It is impossible to start the Control-M monitor until the New Day procedure finishes executing successfully.

The Control-M monitor shuts down.

Corrective Action: Check how the New Day procedure finished executing. All the problems of the New Day procedure must be corrected before restarting the Control-M monitor. Note, however, that if an IPL occurred during the previous run of the New Day procedure, it will correct itself when restarted. Therefore, it can be restarted without correction. If the New Day procedure is abended, it may be necessary to set all dates in the date control record (the DATREC member in the CTM PARM library) to one day prior to the current day and rerun the New Day procedure. If the procedure ends successfully, the user will be able to restart the Control-M monitor.

CTM118S FILE ALLOCATED TO DDNAME "DACKPT" IS NOT THE EXPECTED ACTIVE JOBS FILE

Explanation: Highlighted, unrollable message.

The data set described by the DACKPT DD statement is not the expected Control-M Active Jobs file.

This could be due to one of the following:

Control-M monitor will shut down.

Corrective Action: Correct JCL for the Control-M monitor.

CTM119S ACTIVE JOBS FILE IS DAMAGED - NOTIFY THE IOA ADMINISTRATOR

Explanation: Highlighted, unrollable message.

The contents of the Active Jobs file have been corrupted.

The Active Jobs file is marked as FORMAT during New Day processing, and marked as FREE at successful completion. Currently, the file is not marked as FORMAT, nor as FREE.

Control-M monitor will shut down.

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, call your IOA Administrator.

CTM120I CONTROL-M MONITOR SHUTTING DOWN

Explanation: Highlighted, unrollable message.

This information message is issued by Control-M or Control-D when shutting down the Control-M monitor in response to a P command, or on certain internal Control-M events.

The IOA Log contains additional messages concerning the reason for shutting down.

Control-M monitor shuts down.

Corrective Action: No action is required.

CTM121S CONTROL-M MONITOR ENDED WITH ERROR

Explanation: Highlighted, unrollable message.

Control-M monitor ended with an error.

The IOA Log should contain additional messages concerning the specific error.

Control-M monitor will shut down.

Corrective Action: Check the IOA Log (or the computer log) for the reason. Call the system programmer for assistance if needed. Try to start the Control-M monitor again as soon as possible.

CTM122W YOUR CONTROL-M IS ALREADY ACTIVE. QNAME qName

Explanation: Highlighted, unrollable message.

An attempt has been made to start a Control-M monitor which is already active. Two Control-M monitors with the same qname cannot run at the same time.

The newly started Control-M monitor will shut down.

Corrective Action: No action is required.

CTM123I CONTROL-M INTERVAL IS SET TO nn SECONDS

Explanation: This information message is issued when an operator command is used to set a Control-M sleeping interval. For more details, see the INCONTROL for z/OS Administrator Guide.

Control-M monitor wakes up every nn seconds, and checks what to do.

Corrective Action: No action is required.

CTM124E VALID PARAMETERS FOR KEYWORD keywrd ARE: parms

Explanation: A MODIFY command containing invalid syntax was entered for the Control-M monitor.

In this message, parms is a list of the valid parameters.

Corrective Action: Enter one of the parms parameters.

CTM125I validParm

Explanation: This message indicates that an erroneous parameter was passed to the Control-M monitor by an operator modify command (F). The message follows the CTM103E message with a valid modify parameter.

Corrective Action: Enter a correct modify parameter.

CTM126I NEW EXIT CTMX004 LOADED

Explanation: This information message indicates successful execution of the CTMX004 operator modify command. A new Control-M resource acquisition user exit was loaded.

Corrective Action: No action is required.

CTM127I NEWDEST COMMAND ACCEPTED: NEWDEST= tableName

Explanation: A NEWDEST operator command has been passed successfully to the Control-M monitor.

The Control-M monitor replaces the current destination table with the tableName destination table.

Corrective Action: No action is required.

CTM128S OPEN OF DUAL ACTIVE JOBS FILE FAILED-DDNAME "DAALTCKP"

Explanation: Highlighted, unrollable message.

Open of the Control-M Alternate (dual) Active Jobs file failed (the DAALTCKP DD statement).

This is due to one of the following:

This message will be produced only if Control-M is working in dual file mode, which is selected by setting the DUALDB parameter in the IOAPARM member in the IOA PARM library to Y.

The Control-M monitor will shut down with an error message.

Corrective Action: Correct the JCL for the Control-M procedure, and start it again. If you do not wish to run in dual file mode, correct the Control-M Installation Parameters (IOAPARM).

CTM129W EXIT exitName WAS NOT LOADED

Explanation: Control-M failed to load the exitName user exit. Common reasons for failure are:

Control-M will bypass the exit and continue to run.

Corrective Action: Check the computer Log for the cause of the failure.

CTM12AE CONTROL-M EXTENDED MCS INITIALIZATION FAILED. RC= rc, MCSOPER RC= mcsoper_rc REASON= rsn

Explanation: Initialization of the extended MCS console component of Control-M failed.

The second return code (mcssoper_rc) and the reason code (rsn) are displayed only if the value of rc, the first reason code, is 16 or 20.

Possible values for rc, the first return code, are shown in the following table.

rc

Explanation

8

Authorization failed

12

Version of operating system not supported

16

See the Note below this table.

20

See the Note below this table.

24

There is insufficient memory

32

ENQ for the console already held.

Note:

If the value of rc is 16 or 20, the second return code (mcssoper_rc) and the reason code (rsn) from the MCSOPER facility are also displayed.

All services relying on an extended MCS console function are inoperable.

Corrective Action: Correct the problem according to the return code displayed in the message.

For the meanings of the MCSOPER return and reason codes displayed if the return code is 16 or 20, see the description of the MCSOPER macro in the IBM Application Development Reference - Services for Authorized Assembler Language Programs.

Once the cause of the problem has been corrected, bring the Control-M monitor down and up again.

CTM130E SYNTAX ERROR. "QUIESQRES" COMMAND IGNORED

Explanation: The Control-M monitor attempted to evaluate the QUIESQRES command identified in the preceding CTML18I message, but found invalid command syntax.

For a detailed description of the command syntax, see the section on activating and deactivating quiesced quantitative resources in the Control-M chapter of the INCONTROL for z/OS Administrator Guide.

The Control-M monitor ignores the command.

Corrective Action: Enter another QUIESQRES command using valid syntax.

CTM131I NO QUIESCE TIME ASSIGNED TO RESOURCE resourceName

Explanation: The following command was given:

F CONTROLM,QUIESQRES=resourceName,DISPLAY|OFF

with the DISPLAY or OFF parameter. However, no QUIESCE time was assigned to the resourceName resource.

Corrective Action: No action is required.

CTM132I NO QUIESCE TIME ASSIGNED TO ANY RESOURCE

Explanation: The following command was given:

F CONTROLM,QUIESQRES=resourceName,DISPLAY|OFF

with the DISPLAY or OFF parameter. However, no resource had a QUIESCE time assigned.

Corrective Action: No action is required.

CTM133I yyyy-mm-dd hh:mm QUIESCE TIME ASSIGNED TO RESOURCE resourceName

Explanation: This information message displays the action of the Control-M monitor in response to the following command:

F CONTROLM,QUIESQRES=resourceName,DISPLAY|NOW|OFF|hh:mm

The date and time assigned in response to this command depend on the setting of the DISPLAY | NOW | OFF parameter, as follows:

Corrective Action: No action is required.

CTM145E taskType memName jobName /jobId OID=orderId ERROR IN IOAMEM FUNCTION func : RETURN CODE rc

Explanation: Highlighted, unrollable message.

Internal error in Control-M monitor.

In this message, rc consists of eight digits that include a 4-digit reason code and a 4-digit return code. For more information on these codes, see the description of IOAMEM in the INCONTROL for z/OS Administrator Guide.

Job submission stops. In some cases, the Control-M monitor will shut down.

Corrective Action: Do the following:

CTM14AE JOB memName OID=orderId NOT SUBMITTED, MIGRATED DSN lib WTO for SUB14AE.

Explanation: Highlighted, unrollable message.

The job was not submitted because the library that contains its member migrated.

The job is not submitted and is assigned a NOTOK status with the NOLIB reason.

Corrective Action: Restore the library to disk and submit the job again.

CTM15CI memName... THE MEMBER HAS BEEN COPIED INTO OVERLIB lib

Explanation: The memName member has been copied from the MEMLIB library into the OVERLIB library, because the COPMEM20 installation parameter was set to Y.

Corrective Action: No action is required.

CTM15CW memName... THE MEMBER HAS NOT BEEN COPIED INTO OVERLIB. REASON: rc-rsn. LIBRARY: lib

Explanation: Although the COPMEM20 Control-M installation parameter was set to Y, Control-M failed to copy the memName member into the OVERLIB library.

The variables in this message are:

For explanation of the values of rc and rsn, see the description of the IOAMEM Assembler Macro in the INCONTROL for z/OS Administrator Guide.

Corrective Action: Take corrective action on the basis of the values of rc and rsn.

CTM15DI memName... THE MEMBER HAS BEEN DELETED FROM OVERLIB lib

Explanation: The memName member has been deleted from the lib OVERLIB library, because either the DELOVRER or the DELOVRUN Control-M installation parameter was set to Y.

Corrective Action: No action is required.

CTM15DW memName... THE MEMBER HAS NOT BEEN DELETED FROM OVERLIB. REASON: rc-rsn. LIBRARY: lib

Explanation: Although either the DELOVRER or the DELOVRUN Control-M installation parameter was set to Y, Control-M failed to delete the memName member from the OVERLIB library.

The variables in this message are:

For explanation of the values of rc and rsn, see the description of the IOAMEM Assembler Macro in the INCONTROL for z/OS Administrator Guide.

Corrective Action: Take corrective action on the basis of the values of rc and rsn.

CTM161E taskType memName jobName /jobId OID=orderId SEVERE INTERNAL ERROR WHILE PROCESSING AUTOEDIT INSTRUCTIONS, RC=rc. SUBMISSION CANCELLED

Explanation: Severe Control-M internal error during submission of member.

The error occurred in the AutoEdit language interpreter.

Depending on the severity of the error, Control-M monitor will shut down, or at least job submission will be cancelled.

Corrective Action: Have your system programmer prepare the Control-M monitor full output and contact BMC Customer Support. You will probably be able to submit the member if you change (or omit) your AutoEdit control statements in the member, but keep a copy of the original member for problem resolution. If you hold the job order, Control-M monitor will not shut down.

CTM166E SUBMITTER FAILURE. CTMLIB ABENDED abCode ON FUNCTION func

Explanation: Highlighted, unrollable message.

An abend has occurred while trying to read a member.

The abend code (abCode) and function (func) can suggest the cause of the problem.

Control-M monitor does not abend. Processing of other jobs continues, but the job submission is terminated.

Corrective Action: Resolve the problem according to the abend code and rerun the job.

CTM168S CONTROL-M SHUTTING DOWN - COMMUNICATION TO "JES" NOT AVAILABLE

Explanation: Highlighted, unrollable message.

The Control-M monitor cannot communicate with JES, and therefore shuts down.

This can be due to the following:

The Control-M monitor shuts down as a precaution. If something is wrong with JES, the results of job submission or the initiation of a started task may be unpredictable.

Corrective Action: If the problem is JES-related, after the JES problem is solved, start the Control-M monitor again.

If you cannot find the cause of the problem, have your system programmer prepare the Control-M monitor full output and contact BMC Customer Support. The sysout of the DD statement DADUMP2 of the Control-M monitor procedure should contain a dump of problem-related areas which can help BMC Customer Support.

In any case, try to start Control-M monitor again, for production to continue.

CTM169E SEVERE INTERNAL ERROR WHILE STARTING A STARTED TASK RC=rc. TASK WAS NOT STARTED

Explanation: A severe Control-M monitor error occurred while starting a started task.

The problem is probably in the Control-M monitor communication with JES. The return code rc can be interpreted by BMC Customer Support.

The Control-M monitor may:

Corrective Action: Re-start the Control-M monitor.

CTM170E SEVERE INTERNAL ERROR WHILE RELEASING AN ON SPOOL JOB RC=rc. JOB NOT RELEASED

Explanation: When the On Spool Facility tried to get the status of the job before releasing it, it received an unknown return code rc from the subsystem request.

The job is not released.

Corrective Action: Have your INCONTROL administrator prepare the Control-M monitor full output and contact BMC Customer Support.

CTM180I ENABLED FOR THE AUTOMATIC RESTART MANAGEMENT FUNCTION. ELEMENT elemName

Explanation: This information message is issued by the Control-M monitor when the Automatic Restart Management function is enabled at monitor initialization time.

The Control-M monitor was requested to enable the Automatic Restart Management function under the elemName element name. When this succeeds, this information message is issued.

Corrective Action: No action is required.

CTM181I AUTOMATIC RESTART IN PROGRESS AFTER UNEXPECTED FAILURE

Explanation: If Automatic Restart Management support is enabled and the Control-M monitor fails unexpectedly, this information message is issued when the Control-M monitor is restarted automatically by MVS.

If the Control-M monitor fails unexpectedly when Automatic Restart Management support is enabled, this information message is issued when the Control-M monitor is automatically restarted by MVS.

Corrective Action: No action is required.

CTM182W AUTOMATIC RESTART MANAGEMENT REQUEST FOR ELEMENT elemName FAILED R15=nn REASON=rsn shortDesc

Explanation: This warning message is issued if the Control-M monitor fails to enable the Automatic Restart Management function under the elemName element.

The return and reason codes are documented in the Return and Reason Codes part of the “IXCARM Macro Instruction” section in the IBM manual MVS Programming: Sysplex Services References. The short description is only displayed for common errors.

The Control-M monitor continues without Automatic Restart Management support.

Corrective Action: Investigate why the enable request was refused and rectify the situation.

CTM183E JOB WAS PUT ON HOLD BY THE AUTOMATIC RECOVERY FEATURE

Explanation: Highlighted, unrollable message.

A job was put into Held status after a subtask abended.

As a result of the abending of the subtask, the CTM114E message is issued. If the MAXJBHLD parameter in the CTMPARM member is set to a value greater than zero, this message is issued following the CTM114E message.

The MAXJBHLD parameter sets the maximum number of jobs that can be put into Held status.

Corrective Action: No action is required.

CTM184E MAXIMUM NUMBER REACHED FOR AUTOMATIC RECOVERY FEATURE - DISABLED

Explanation: A job was previously put into Held status after a subtask abended. As a result of the abending of the subtask, the CTM114E and CTM183E messages are issued.

This message is issued following the CTM183E message if both the following conditions are satisfied:

The MAXJBHLD parameter sets the maximum number of jobs that can be put into Held status.

Corrective Action: No action is required.

CTM188W subtaskName IS PROCESSING JOB jobName ORDID orderId FOR MORE THAN number MINUTES

Explanation: The subtaskName subtask has been processing the job for an unreasonable amount of time. The task is most likely hung or in a loop.

Possible causes are:

The Control-M monitor continues processing as usual. The subtask continues processing of the indicated job.

Note that the jobname and orderID might not be specified in the message if the issue was detected before these fields were populated.

Corrective Action: Review the system log for additional messages related to the problem.

If the reason for the problem is unclear, take the system (SVC) dump of the Control-M monitor's address space using the DUMP console command. Specify parameter SDATA=(CSA,GRSQ,SUM,RGN,TRT).

If the problem is outside Control-M, holding the job being processed and restarting the Control-M monitor may have only temporary effect.

CTM1A3S OID=orderId SEVERE INTERNAL ERROR READING AJF. RC=rc

Explanation: Severe error on Control-M Active Jobs file.

Possible causes are:

The 2TF Control-M program ends with errors.

Corrective Action: Have your INCONTROL administrator prepare the Control-M monitor full output and contact BMC Customer Support. Check if the file has been updated from multiple computers without global ENQ control, or updated by an unauthorized program.

CTM1A6S OPEN OF STATISTICS FILE FAILED. RC=rc ERROR=errCode

Explanation: Open of Control-M Job Statistics file failed.

Possible causes are:

Corrective Action: Look for VSAM messages or other system messages, and correct the JCL for the Control-M monitor procedure.

CTM1ADW VM COMMAND OUTPUT TRUNCATED

Explanation: The response of the IOA VM command interface exceeded the 4096 bytes that the buffer can hold. The remainder of the response is truncated.

Corrective Action: Change the command so it can be held in the available buffer of 4096 bytes.

Parent Topic

CTM messages