This group includes messages for the Control-D, Control-D/Image, and Control-D/Page on Demand products.
Explanation: This information message indicates that the CTDBLXRP utility has begun processing.
The CTDBLXRP utility rebuilds Print Control Records in the Active User Report List file.
Corrective Action: No action is required.
Explanation: This information message indicates that the CTDBLXRP utility has successfully completed execution.
The CTDBLXRP utility rebuilds Print Control Records in the Active User Report List file.
The CTDBLXRP utility terminates with a condition code of 0.
Corrective Action: No action is required.
Explanation: The CTDBLXRP utility, which rebuilds Print Control Records in the Active User Report List file, encountered a critical error during execution.
The utility terminates with a condition code of 8 or higher.
Corrective Action: Check the IOA Log file and system log for previous messages associated with the error. Correct the problem and re-execute the utility.
Explanation: The CTDBLXRP utility, which rebuilds Print Control Records in the Active User Report List file, encountered an error while performing the func function.
The error associated with each return code (rc) is identified below.
rc |
Explanation |
---|---|
008 |
Memory shortage. |
012 |
Memory shortage. |
016 |
Invalid function. |
020 |
Database I/O error. |
024 |
Open error. |
Processing terminates.
Corrective Action: Check the IOA Log file and system log for additional messages associated with the error. Determine the cause of the error, correct the problem, and re-execute the utility. If the problem persists, contact BMC Customer Support.
Parent Topic |