This group includes messages for the Control-M/Analyzer product.
Explanation: This information message indicates the normal start of the CTBJAFDL utility.
Corrective Action: No action is required.
Explanation: The CTBJAFDL or CTBJAFCP utility failed because of a syntax error in the stmt statement.
The utility stops executing with a condition code of 08.
Corrective Action: Correct the indicated statement and rerun the job.
Explanation: The CTBJAFDL or CTBJAFCP utility failed to open the print file referenced by the SYSPRINT DD statement.
The failure may be due to one of the following:
The utility stops executing with a condition code of 16.
Corrective Action: Correct the JCL and rerun the job.
Explanation: The CTBJAFDL or CTBJAFCP utility failed to open the input file referenced by the SYSIN DD statement.
The failure may be due to one of the following:
The utility stops executing with a condition code of 16.
Corrective Action: Correct the JCL and rerun the job.
Explanation: The CTBJAFDL or CTBJAFCP utility failed to perform the opn operation on the Rule Activity file. The accompanying return code is indicated in the CTBA07I message.
If processing of the current record fails, processing continues with the next record. In some cases, for example, if the file could not be opened, processing stops.
Corrective Action: Notify your INCONTROL administrator.
Explanation: The CTBJAFDL or CTBJAFCP utility failed to perform the opn operation on the Control-M/Analyzer report file. The accompanying return code is indicated in the CTBA07I message.
If processing of the current record fails, processing continues with the next record. In some cases, for example if the file could not be opened, processing is stopped.
Corrective Action: Notify your INCONTROL administrator.
Explanation: The CTBJAFDL or CTBJAFCP Control-M/Analyzer utility could not lock a database file referenced by the DD name in the DD statement when trying to update it.
The CTBJAFDL or CTBJAFCP Control-M/Analyzer utility stops execution with a nonzero return code.
Corrective Action: Check the reason for a conflict and rerun the Control-M/Analyzer utility after the concurrent applications have finished running.
Explanation: This information message indicates the return code resulting from execution of the CTBJAFDL or CTBJAFCP utility.
Corrective Action: No action is required.
Explanation: The first input statement for the CTBJAFDL utility must be, but was not, statement DAYS.
The utility stops executing with a condition code of 08.
Corrective Action: Correct the input statement and rerun the job.
Explanation: The CTBJAFDL or CTBJAFCP utility failed to perform a FREEMAIN operation. The accompanying return code is indicated in the CTBA07I message.
The utility stops executing.
Corrective Action: Notify your INCONTROL administrator.
Explanation: This information message indicates the successful deletion of jobs by the CTBJAFDL utility. This message precedes the CTBA11I, CTBA12I, and CTBA13I messages, which display the list of deleted jobs.
Corrective Action: No action is required.
Explanation: This information message indicates the number of job entries that have been copied to the target Rule Activity file by the CTBJAFCP Control-M/Analyzer utility.
Corrective Action: No action is required.
Explanation: This information message indicates the number of primary report entries that have been copied to the target report file by the CTBJAFCP Control-M/Analyzer utility.
Corrective Action: No action is required.
Explanation: The CTBJAFCP utility failed to copy of the Rule Activity file because the target file is full. The accompanying return code is indicated in the CTBA07I message.
The utility stops executing.
Corrective Action: Compress the Report file by running the CTBJAFDL Control-M/Analyzer utility.
Explanation: The CTBJAFCP utility failed to copy of the Rule Activity file because the target file is full. The accompanying return code is indicated in the CTBA07I message.
The utility stops executing.
Corrective Action: Compress the Report file by running the CTBJAFDL utility.
Explanation: This information message indicates the number of job entries that were deleted from the Rule Activity File by the CTBJAFDL Control-M/Analyzer utility.
Corrective Action: No action is required.
Explanation: This information message consists of a series of titles for the information provided in the CTBA13I message.
Corrective Action: No action is required.
Explanation: The CTBA12I and CTBA13I information messages form a chart listing job entries that were deleted from the Rule Activity file by the C TBJAFDL Control-M/Analyzer utility.
The CTBA13I message is repeated once for each job entry that was deleted.
Corrective Action: No action is required.
Explanation: This information indicates the normal start of the CTBJAFCP Control-M/Analyzer utility.
Corrective Action: No action is required.
Explanation: The CTBJAFDL utility requires more memory to compress the Rule Activity file and the report file.
The utility stops executing with a condition code of 12.
Corrective Action: Increase the REGION size and rerun the job.
Explanation: The CTBJAFCP utility requires more memory to copy the Rule Activity file and the report file.
The utility stops executing with a condition code of 12.
Corrective Action: Increase the REGION size and rerun the job.
Explanation: The CTBDBF4 Control-M/Analyzer utility failed to open the target file referenced by the DAOUT DD statement.
The failure may be due to one of the following:
The utility terminates with a condition code of 116.
Corrective Action: Correct the JCL and rerun the job.
Explanation: The CTBDBF4 Control-M/Analyzer utility failed to open the print file referenced by the SYSPRINT DD statement.
The failure may be due to one of the following:
The utility terminates with a condition code of 120.
Corrective Action: Correct the JCL and rerun the job.
Explanation: The CTBDBF4 Control-M/Analyzer utility requires more memory to format the target file.
The utility terminates with a condition code of 112.
Corrective Action: Increase the REGION size and rerun the job.
Explanation: This information message indicates that the lin input line was erroneous. An error message detailing the problem follows this message.
Corrective Action: No action is required.
Explanation: The line structure was not in the format item= value. Input lines with parameters for the CTBVXRF cross-reference utility must be formatted item= value.
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the utility parameters and rerun the utility.
For more information, see the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide.
Explanation: The input statement to the CTBVXRF cross-reference utility did not include the parameter identified in the message.
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the error and rerun the CTBVXRF utility.
For more information, see the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide.
Explanation: The input statement to the CTBVXRF cross-reference utility did not include the parameter identified in the message.
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the error and rerun the CTBVXRF utility.
For more information, see the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide.
Explanation: The input statement to the CTBVXRF cross-reference utility did not include the parameter identified in the message.
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the error and rerun the CTBVXRF utility.
For more information, see the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide.
Explanation: The current input line specified an unexpected parameter. The input to cross-reference The CTBVXRF utility consists of parameters specified in a predefined order.
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the error and rerun the CTBVXRF utility. See the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide for more information.
Explanation: The sort option was incorrect. The Cross-Reference Report may be sorted either by rule name (option RULE) or by variable name (option VAR).
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the error and rerun the utility.
For more information, see the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide.
Explanation: The value of the BLOCKS option for the CTBVXRF cross-reference utility was not YES or NO.
The BLOCKS option specifies whether or not to include the block name in the cross-reference report. Its value must be YES or NO.
The CTBVXRF cross-reference utility terminates with an error.
Corrective Action: Correct the error and rerun the utility. For more information, see the CTBVXRF cross-reference utility in the INCONTROL for z/OS Utilities Guide.
Explanation: This information message indicates that the CTBDBVCG Control-M/Analyzer utility, which changes the number of generations, has started running.
Corrective Action: No action is required.
Explanation: The CTBDBVCG Control-M/Analyzer utility detected an error in the GROUP input statement.
The CTBDBVCG Control-M/Analyzer utility stops executing with a condition code of 32.
Corrective Action: Correct the GROUP input statement and rerun the job. For more information, see the description of the GROUP input statement in the Control-M/Analyzer User Guide.
Explanation: The CTBDBVCG Control-M/Analyzer utility detected an error in the VARIABLE input statement.
The CTBDBVCG Control-M/Analyzer utility stops executing with a condition code of 32.
Corrective Action: Correct the VARIABLE input statement and rerun the job. For more information, see the description of the VARIABLE input statement in the Control-M/Analyzer User Guide.
Explanation: Processing of the Control-M/Analyzer Model failed.
The utility stops executing with a nonzero condition code.
Corrective Action: Provide your INCONTROL administrator with the sysout of the CTBDBVCG utility.
Explanation: Processing of the Control-M/Analyzer Variables Definition or Variables Generations failed.
The utility stops executing with a nonzero condition code.
Corrective Action: Provide your INCONTROL administrator with the sysout of the CTBDBVCG. utility.
Explanation: The CTBDBVCG utility could not update the Control-M/Analyzer Variables Generations file because it was full.
The CTBDBVCG utility stops executing with a nonzero condition code.
Corrective Action: Enlarge the Control-M/Analyzer Variables Generations file or decrease the value of the NUMGEN input parameter and rerun the job.
Explanation: The CTBDBVCG utility could not update the Control-M/Analyzer Variables Definition file because it was full.
The CTBDBVCG utility stops executing with a nonzero condition code.
Corrective Action: Enlarge the Control-M/Analyzer Variables Definition file or decrease the value of the NUMGEN input parameter and rerun the job.
Explanation: The CTBDBVCG Control-M/Analyzer utility detected an error in the NUMGEN input statement.
The CTBDBVCG Control-M/Analyzer utility stops executing with a condition code of 32.
Corrective Action: Correct the NUMGEN input statement and rerun the job. For more information, see the description of the NUMGEN input statement in the Control-M/Analyzer User Guide.
Explanation: The CTBDBVCG Control-M/Analyzer utility failed to open the input file referenced by the DACMD DD statement.
Possible causes are:
The utility stops executing with a condition code of 16.
Corrective Action: Correct the JCL accordingly and rerun the job.
Explanation: The CTBDBVCG Control-M/Analyzer utility failed to open the Control-M/Analyzer database.
The utility stops executing with a nonzero condition code.
Corrective Action: Verify that the correct Control-M/Analyzer database was allocated to the CTBDBVCG utility and rerun the job.
Explanation: There is insufficient memory for the CTBDBVCG Control-M/Analyzer utility to update the database.
The CTBDBVCG utility stops executing with a condition code of 12.
Corrective Action: Increase the region size for the CTBDBVCG utility, and rerun the job.
Explanation: The CTBDBVCG Control-M/Analyzer utility failed to open the print file referenced by the DCBOUT DD statement.
The failure might be due to one of the following reasons:
The CTBDBVCG utility stops executing with a condition code of 8.
Corrective Action: Correct the JCL accordingly and rerun the job.
Explanation: This information message indicates that no input statements were specified for the CTBDBVCG Control-M/Analyzer utility.
The CTBDBVCG utility stops executing with a condition code of 4.
Corrective Action: Insert GROUP and/or VARIABLE input statements in the JCL and rerun the job.
Explanation: This information message indicates that the CTBDBVCG Control-M/Analyzer utility found no database records that satisfy the specified input criteria.
The CTBDBVCG utility stops executing with a condition code of 4.
Corrective Action: Correct the GROUP and/or VARIABLE input statements in the JCL and rerun the job.
Parent Topic |