Previous Topic

Next Topic

Book Contents

Book Index

Messages CTB400 through CTB4xx

This group includes messages for the Control-M/Analyzer product.

CTB401E INTERNAL PROGRAM ERROR - INVALID FUNCTION

Explanation: An internal error has occurred.

The requested function is not performed.

Corrective Action: Ask your INCONTROL administrator to call BMC Customer Support.

CTB402E INSUFFICIENT STORAGE FOR INVOCATION LIST

Explanation: There is insufficient storage to perform the requested action.

Corrective Action: Either ask your INCONTROL administrator to call BMC Customer Support, or adjust the selection criteria so that fewer records are selected.

CTB403E INTERNAL PROGRAM ERROR IN ROUTINE CTBCKP

Explanation: An internal error occurred.

The requested action is not performed.

Corrective Action: Ask your INCONTROL administrator to call BMC Customer Support.

CTB405E OPEN OF DDNAME ddName FAILED. RC= rc

Explanation: Control-M/Analyzer was unable to open the file referenced by the ddName DD statement.

The requested action is not performed.

Corrective Action: Check that the ddName DD statement exists and refers to the correct file. Check the system log for messages which indicate the reason that the open failed. If you are unable to solve the problem, report the contents of the message to your INCONTROL administrator.

CTB406E DISPLAY TYPE " type" NOT FOUND

Explanation: The user specified a display type (type) which has not been defined. Valid display types are defined in the $$JBL member.

Corrective Action: Specify a valid display type.

CTB407E PLEASE SPECIFY A GROUP NAME, OR "*" FOR ALL GROUPS

Explanation: A value was not specified in the GROUP field. GROUP is a required field.

Corrective Action: Specify a group name (or * for all groups).

CTB408E REPORT NOT FOUND FOR THIS JOB

Explanation: The report for this invocation cannot be located in the report file. The report file is not synchronized with the Active Balancing file.

The requested action is not performed.

Corrective Action: Notify your INCONTROL administrator.

CTB409E REPORT NOT CREATED FOR THIS JOB

Explanation: No report was created for this invocation of Control-M/Analyzer. Either the report file is full, or an internal error occurred in the early stages of Control-M/Analyzer invocation.

The requested action is not performed.

Corrective Action: Notify your INCONTROL administrator.

CTB40AI NO VARIABLES WERE COMMITTED FOR THIS ENTRY

Explanation: This information message indicates that the mission did not commit any variables.

Corrective Action: No action is required.

CTB40BE INVALID RETURN CODE FROM modName RC = rc FUNCTION func

Explanation: An internal error occurred.

The requested action is not performed.

Corrective Action: Ask your INCONTROL administrator to call BMC Customer Support.

CTB40CI ROLLBACK COMPLETED SUCCESSFULLY

Explanation: This information message indicates that rollback was performed successfully.

Corrective Action: No action is required.

CTB40DE ROLLBACK DENIED BY SECURITY EXIT

Explanation: This information message indicates that you are not authorized to roll back this invocation.

Corrective Action: If you think you should be authorized to roll back this invocation, contact your security administrator.

CTB40EI ALL COMMITTED VARIABLES HAVE BEEN OVERWRITTEN

Explanation: This information message indicates that all the variables that were committed by this invocation have been overwritten.

Corrective Action: No action is required.

CTB40FI PRINT REQUEST COMPLETED SUCCESSFULLY

Explanation: This information message indicates that the requested report has been sent to the spool or to a file.

Corrective Action: No action is required.

CTB410S SYSOUT ALLOCATION FAILED, RC= rc, ERROR= error

Explanation: Control-M/Analyzer was unable to perform the dynamic allocation required to print your report.

Corrective Action: Refer to the IBM manual MVS Programming: Authorized Assembler Services Guide. If you still cannot solve the problem, ask your INCONTROL administrator to call BMC Customer Support.

CTB411S SYSOUT OPEN FAILED

Explanation: SYSOUT could not be opened for report printing.

Corrective Action: Notify your INCONTROL administrator.

CTB413E COP# MUST BE 3 DIGITS (001-255)

Explanation: An invalid number of copies of the report was requested. The number of copies of a report must be a three digit number between 001 and 255.

Corrective Action: Correct the request and try again.

CTB414E SECOND PART OF DESTINATION AND WRITER NAME CANNOT BE MIXED

Explanation: A value was specified in both the WTR field and the second part of the destination field. Values for both cannot be used together; they are mutually exclusive.

Corrective Action: Specify either value, but not both values.

CTB415E YOU ARE NOT AUTHORIZED TO PERFORM THIS ACTION

Explanation: The security exit prevents you from performing the action you have requested.

Corrective Action: If you think you should be authorized to perform this action, contact your security administrator.

CTB416E DATASET NAME CANNOT BE BLANK

Explanation: A data set name was not specified with the request to print a file. If you choose to print a file, you must specify a data set name.

Corrective Action: Specify the data set name if you want to print the file.

CTB417S FILE OPEN FAILED

Explanation: While processing the print request, Control-M/Analyzer was unable to open the specified file.

The requested action is not performed.

Corrective Action: Check that the data set is cataloged. Check the system log for error messages which may indicate a reason for the problem, and correct accordingly.

CTB418S UNABLE TO PRINT REPORT

Explanation: This error occurs when there are no lines to be printed.

Corrective Action: Notify your INCONTROL administrator.

CTB419S INSUFFICIENT FREE SPACE IN THE OUTPUT FILE

Explanation: Control-M/Analyzer was unable to print the report because there was insufficient space in the output file.

Corrective Action: Enlarge the output file and try again.

CTB41AI THIS INVOCATION HAS ALREADY BEEN ROLLED BACK

Explanation: This information message indicates that a roll back request was made for an invocation that has already been rolled back.

Corrective Action: No action is required.

CTB41BE REQUESTED FILE IS NOT CATALOGED

Explanation: Control-M/Analyzer was unable to open the specified file.

The requested operation is not performed.

Corrective Action: Make sure the data set is cataloged.

CTB41CE REQUESTED FILE IS NOT SEQUENTIAL

Explanation: The user specified a nonsequential file for the online print option. Control-M/Analyzer cannot print the balancing report into nonsequential file.

Corrective Action: Correct the DSN specified in the Print Option panel.

CTB484I POST DAILY CHECKPOINT WRITTEN

Explanation: This information message indicates that Post-daily checkpoint was written and that the New Day procedure ended normally.

Corrective Action: No action is required.

Parent Topic