Messages CSF300 through CSF3xx

This group includes messages for the Control-O product.

CSF321S ERROR OPENING REPORT FILE

Explanation: The CTOCSF program was unable to open the file specified in the SYSPRINT DD statement. The SYSPRINT DD statement is either not specified in the JCL, or is specified incorrectly.

The CTOCSF program ends with a return code of 08.

Corrective Action: Check and correct the JCL job.

CSF322S ERROR OPENING STATISTICS INPUT FILE

Explanation: The source Statistics file cannot be opened. The CTOCSF program is unable to open the file referenced by the DASTF DD name.

Possible causes are:

The CTOCSF program ends with a return code of 08.

Corrective Action: Do either or both of the following:

CSF323S INSUFFICIENT SPACE IN TARGET FILE

Explanation: The new Statistics file is not large enough to contain all the records listed in the source Statistics file.

The CTOCSF program ends with a return code of 08.

Corrective Action: Create a larger Statistics file and resubmit the job.

CSF324W ERROR CLOSING STATISTICS INPUT FILE

Explanation: An internal error was encountered while closing the source Statistics file referenced by the DD name DASTF.

The CTOCSF program ends with a return code of 08.

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, contact your INCONTROL administrator.

CSF325S ERROR OPENING STATISTICS OUTPUT FILE

Explanation: Control-O was unable to open the target Statistics file specified in the CTOPARM member.

The CTOCSF program ends with a return code of 08.

Corrective Action: Check the JCL and the CTOPARM member for errors and resubmit the job.

CSF326S STATISTICS FILE DYNAMIC ALLOCATION ERROR rc/rsn/dsn

Explanation: Dynamic allocation of the dsn Statistics file failed with a return code of rc and a reason code of rsn.

The CTORSTM Statistics Report utility terminates with a return code of 08.

Corrective Action: Examine the IBM manual MVS Programming: Authorized Assembler Services Guide to determine the cause of the error, and correct the error accordingly. If not successful, contact your INCONTROL administrator.

CSF327W ERROR CLOSING STATISTICS OUTPUT FILE

Explanation: An internal error was encountered while closing the target Statistics file. This message may be accompanied by an MVS message explaining the error. If such a message is issued, your system programmer may be able to fix the problem.

The CTOCSF program ends with a return code of 08.

Corrective Action: Call your system programmer for assistance. If the problem is not resolved, contact your INCONTROL administrator.

CSF328I COPY OF STATISTICS FILE ENDED OK

Explanation: This information message indicates that the Statistics file was successfully copied by the CTOCSF utility.

Corrective Action: No action is required.

CSF329I COPY OF STATISTICS FILE STARTED

Explanation: This information message indicates that the CTOCSF utility has begun copying the Statistics file.

Corrective Action: No action is required.