This group includes messages for the Control-O product.
Explanation: This information message indicates that the IOACLCND utility started.
Corrective Action: No action is required.
Explanation: This information message indicates that the cleaning of the IOA Conditions file by the IOACLCND utility ended successfully.
Corrective Action: No action is required.
Explanation: The data set described by the DASINC DD statement is not IOA Synchronization file. This message is produced by the IOACLCND IOA utility.
Possible causes are:
The utility stops executing.
Corrective Action: Correct the JCL for the job.
Explanation: An invalid parameter was passed to the IOACLCND utility.
In this message, parm identifies the invalid parameter.
For a list of valid parameters, see the IOACLCND utility in the INCONTROL for z/OS Utilities Guide.
The utility stops executing with a condition code of 08.
Corrective Action: Correct the parameter line.
Explanation: A subparameter of a parameter to the IOACLCND utility is missing. A subparameter is expected after the parm parameter.
For valid syntax, see the IOACLCND utility in the INCONTROL for z/OS Utilities Guide.
The utility stops executing with a condition code of 08.
Corrective Action: Correct the parameter line.
Explanation: There is a redundant parameter in a parameter line for the IOACLCND utility.
For details, refer to the IOACLCND utility in the INCONTROL for z/OS Utilities Guide.
The utility stops executing with a condition code of 08.
Corrective Action: Correct the parameter line.
Explanation: This error is the result of a previous error in the IOACLRES utility. A previous message contains the reason for not cleaning the Conditions file.
The utility stops executing.
Corrective Action: Correct the problem and rerun the utility.
Explanation: This information message indicates that the specified condition was successfully deleted from the IOA Conditions file by the IOACLCND utility or by New Day processing.
Corrective Action: No action is required.
Explanation: The date range specified in the FROM/TO parameter is greater than one year (the IOACLRES utility). The TO date is greater than the FROM date by more than a year. There is no way to IGNORE more than one year.
The utility stops executing with a condition code of 08.
Corrective Action: Correct the parameters and rerun.
Parent Topic |