Messages BLD900 through BLD9xx

This group includes messages for the Control-M for z/OS, Control-M/Assist, Control-M/Links for z/OS, and Control-M/Restart products.

BLD971S OPEN OF CONTROL-M {ACTIVE | HISTORY} JOBS FILE FAILED

Explanation: Either the FORMCKP utility, which allocates and formats the Active Jobs file, or the FORMHST utility, which allocates and formats the Active History file, failed to open the file for formatting.

Possible causes are:

The utility ends with a condition code of 08.

Corrective Action: If a DD statement is missing, add the correct DD statement and rerun the job. If the problem is memory, specify a higher value for the REGION parameter.

BLD972I BUILDING OF CONTROL-M {ACTIVE | HISTORY} JOBS FILE STARTED

Explanation: This information message indicates the normal start of one of the following Control-M utilities:

Corrective Action: No action is required.

BLD973I BUILDING OF CONTROL-M {ACTIVE | HISTORY} JOBS FILE ENDED

Explanation: This information message indicates the normal termination of one of the following Control-M utilities:

Corrective Action: No action is required.

BLD974S CONTROL-M {ACTIVE | HISTORY} JOBS FILE WAS NOT BUILT.

Explanation: Either the FORMCKP utility, which allocates and formats the Active Jobs file, or the FORMHST utility, which allocates and formats the Active History file, failed.

Corrective Action: Check the previous error messages which describe the type of error, and correct the problem accordingly.

BLD975S CONTROL-M {ACTIVE | HISTORY} JOBS FILE WRITE ERROR

Explanation: An I/O error occurred while formatting the Control-M Active Jobs file or History Jobs file. This error may be caused by an incompatibility between the installation parameters, which are contained in CTMPARM, that define the Active Jobs file or the History Jobs file, and the JCL SPACE and DCB parameters.

The utility stops executing with a condition code of 08.

Corrective Action: Correct either the JCL or the Installation Parameters file.

BLD976S OPEN OF IOA LOG FILE FAILED

Explanation: The FORMCKP utility, which is used to allocate and format the Active Jobs file, could not open the IOA Log.

Possible causes are:

The utility stops executing with a condition code of 08.

Corrective Action: Correct the JCL and rerun the job. For more information about the FORMCKP utility, see the INCONTROL for z/OS Utilities Guide.

Parent Topic

BLD messages