Previous Topic

Next Topic

Book Contents

Book Index

Messages ALO300 through ALO3xx

This group includes messages for the Control-O CMEM product.

ALO303S {CONTROL-O | CTMCMEM} AUTOMATION LOG INITIALIZATION ERROR

Explanation: The Automation Log subtask detected an error while initializing.

The subtask and the Control-O or CMEM monitor shuts down. Before shutting down, the Control-O or CMEM monitor attempts to start a new Control-O or CMEM monitor to replace itself. If it does not succeed after a few attempts, Control-O or CMEM ceases trying.

Corrective Action: Contact your INCONTROL administrator.

ALO304S CONTROL-O AUTOMATION LOG SWAPPING ERROR

Explanation: The Automation Log subtask detected a problem when swapping the log.

If the subtask handled the problem, Control-O continues to work as if AUTOMLOG was set to N in the CTOPARM member. Subsequent traces of rules are written to the DAACTLOG sysout of the Control-O monitor.

If the subtask could not handle the problem, the subtask and the monitor may shut down. Before shutting down, the Control-O monitor attempts to start a new Control-O monitor to replace itself. If it does not succeed after a few attempts, Control-O ceases trying.

Corrective Action: Contact your INCONTROL administrator.

ALO305S {CONTROL-O | CTMCMEM} AUTOM. LOG SEVERE ERROR ID= err

Explanation: The Automation Log subtask detected an internal logic problem.

In this message, err is the identifying number of the error.

The subtask and the Control-O or CMEM monitor shut down. Before shutting down, the Control-O or CMEM monitor attempts to start a new Control-O or CMEM monitor to replace itself. If it does not succeed after a few attempts, Control-O or CMEM ceases trying.

Corrective Action: Report the value of err to your INCONTROL administrator.

ALO306S ERROR DETECTED DURING LOGGING

Explanation: The Automation Log subtask detected an internal error while logging a record.

The subtask continues to work, but some records may be lost from the Automation Log.

Corrective Action: Contact your INCONTROL administrator.

ALO307E PROBLEMS WITH WRITEF. LOG SWAPPED

Explanation: The Automation Log subtask detected a problem while trying to commit changes in the Automation Log file.

Control-O continues to work as if AUTOMLOG was set to N in the CTOPARM member. Subsequent traces of rules are written to the DAACTLOG sysout of the Control-O monitor.

Corrective Action: Contact your INCONTROL administrator.

ALO308E AUTOMATION LOG I/O ERROR. RC = rc

Explanation: The Automation Log subtask detected an I/O error while trying to perform an operation on the Automation Log file.

In this message, rc is the return code generated by the error.

If the subtask handled the problem, Control-O continues to work as if AUTOMLOG was set to N in the CTOPARM member. Subsequent traces of rules are written to the DAACTLOG sysout of the Control-O monitor.

If the subtask cannot handle the problem, the subtask and the monitor may shut down. Before shutting down, the Control-O monitor attempts to start a new Control-O monitor to replace itself. If it does not succeed after a few attempts, Control-O ceases trying.

Corrective Action: Check operating system messages detailing the return code (rc) and the cause of the error, for example, disk failure, incorrect data set, or incorrect name or allocation parameters. Correct the cause of the error accordingly.

Parent Topic

ALO messages