Deactivating the Control-D Monitor

To shut down the Control‑D monitor, issue operator command

P CONTROLD

After a few seconds (a maximum of a minute), the monitor shuts down and the following messages are displayed on the operator console:

CTD107I SHUT DOWN UPON REQUEST FROM OPERATOR

CTD136I STOPPING THE PRINTERS Control MONITOR monitor‑name

CTD779I monitorName Control‑D PRINTERS Control MONITOR ENDED

CTD120I Control‑D MONITOR SHUTTING DOWN

Message CTD779I is highlighted. Message CTD120I is highlighted and unrollable.

In case of emergency, you can cancel the Control‑D monitor. However, this is not recommended. If the monitor is cancelled, you must also cancel the Printers Control monitors and secondary monitors.

When you shut down the Control‑D monitor, all other Control‑D facilities (the Compressed Dataset Access Method, IOA Online monitors, IOA Archive Server) and Online facility sessions can remain active.

Parent Topic

Initialization, Customization, and Administration Features