Verify that the IOA Gateway has been successfully installed before trying to start IOAGATE. For information about installing the IOA Gateway, see the IOA chapter in the INCONTROL for z/OS Installation Guide: Installing.
Verify that Control‑O table CTOGATEI is loaded from the Control‑O Rules library. This rule table includes a set of rules that executes the remote request. It must be loaded for every Control‑O monitor that communicates using IOAGATE, Sysplex or Control‑O/COSMOS in a Sysplex.
S IOAGATE |
ECAPARM communication parameters (APPLIDS, PORT) can be overridden by parameters specified in the EXEC PARM of IOAGATE. For information about ECAPARM parameters, see the IOA chapter of the INCONTROL for z/OS Installation Guide: Installing.
For example
S IOAGATE,APPLID=CTOLUA1 |
The Control‑O Application Server (called CTOAS) is automatically activated by the IOA Gateway.
P IOAGATE |
This also deactivates the Control‑O Application Server (CTOAS).