Replacing the Dynamic Destination Table (IOADEST)

The Dynamic Destination table is loaded when the respective INCONTROL product monitor is started. To replace the current Dynamic Destination table with a new one, use the appropriate operator command for each INCONTROL product installed at your site, as described in the following table:

Table 53 Operator Commands for Replacing the Dynamic Destination member

Command Syntax

Product

F CONTROLM,NEWDEST

Control‑M

F CONTROLD,NEWDEST

Control‑D

F CONTROLO,NEWDEST

Control‑O

F IOAFMON,NEWDEST

The IOA Functional monitor used by Control‑M/Tape

The IOADEST table is reloaded and an accompanying message is displayed on the operator console from which the modify command was issued, when the monitor resumes job processing.