The following tables describe the structures of the SMF Alerts solution rules.
Table 64 SMF Dataset Resides on a Non-Direct Access VolumesRule Structure
Item  | 
Description  | 
|---|---|
Title  | 
SMF Dataset Resides on a Non-Direct Access Volumes  | 
Name  | 
IEE3631  | 
Table  | 
SMF  | 
Message  | 
IEE363I SMF ser NOT DIRECT ACCESS  | 
Message Description  | 
SMF dataset SYS1.MANx resides on a non-direct access device and therefore cannot be used by SMF.  | 
Basic Scheduling Parameters  | 
Always schedule this rule.  | 
Runtime Scheduling  | 
IN !CTO-IEE363I-THRESH STAT  | 
Global Variables  | 
None.  | 
Rule Logic  | 
The rule is triggered when the SYS1.MANx dataset resides on a non-direct access device. Control-O immediately brings the error to the attention of the system administrator who can then determine the cause of the problem and proceed to solve it.  | 
Rule Actions  | 
Sends a message notifying user U-SYSADMIN of the problem.  | 
Activating the Rule  | 
Once ordered, the rule remains active until message IEE363I exceeds a predefined threshold. (For more information regarding threshold handling, see SMF Rule Thresholds.)  | 
Recommended  | 
This rule must be activated in PROD mode. The SolveWare category for this rule is 1—little or no customization is required before implementation.  | 
Table 65 SI/O Error While Writing on SMF Dataset Rule Structure
Item  | 
Description  | 
|---|---|
Title  | 
SI/O Error While Writing on SMF Dataset  | 
Name  | 
IEE3641  | 
Table  | 
SMF  | 
Message  | 
IEE364I SMF {LOGICAL | PHYSICAL} I/O ERROR ON SYS1.MANx {FEEDBACK CODE = fc | error text}  | 
Message Description  | 
An I/O error occurred while writing on the SYS1.MANx dataset indicated in the message.  | 
Basic Scheduling Parameters  | 
Always schedule this rule.  | 
Runtime Scheduling Parameters  | 
No special considerations  | 
Global Variables  | 
None.  | 
Rule Logic  | 
The rule is triggered when an error occurs while writing on SYS1.MANx. Control-O immediately brings the error to the attention of the system administrator who can then determine the cause of the problem and proceed to solve it.  | 
Rule Actions  | 
Sends a message notifying user U-SYSADMIN of the problem.  | 
Activating the Rule  | 
Once ordered, the rule remains active until message IEE364I exceeds a predefined threshold. (For more information regarding threshold handling, see SMF Rule Thresholds.)  | 
Recommended Mode or Category  | 
This rule must be activated in PROD mode. The SolveWare category for this rule is 1—little or no customization is required before implementation.  | 
Table 66 SMF Dataset or SYS1.PARMLIB Cannot Be Opened Rule Structure
Item  | 
Description  | 
|---|---|
Title  | 
SMF Dataset or SYS1.PARMLIB Cannot Be Opened  | 
Name  | 
IEE3651  | 
Table  | 
SMF  | 
Message  | 
IEE365I SMF SYS1.{MANx | PARMLIB} NOT OPENED  | 
Message Description  | 
SMF failed to open SMF dataset SYS1.MANx or SYS1.PARMLIB. No records are written to the SMF dataset.  | 
Basic Scheduling Parameters  | 
Always schedule this rule.  | 
Runtime Scheduling Parameters  | 
No special considerations  | 
Global Variables  | 
None.  | 
Rule Logic  | 
The rule is triggered when SYS1.MANx or SYS1.PARMLIB cannot be opened. Control-O immediately brings the error to the attention of the system administrator who can then determine the cause of the problem and proceed to solve it.  | 
Rule Actions  | 
Sends a message notifying user U-SYSADMIN of the problem.  | 
Activating the Rule  | 
Once ordered, the rule remains active until message IEE365I exceeds a predefined threshold. (For more information regarding threshold handling, see SMF Rule Thresholds.)  | 
Recommended Mode or Category  | 
This rule must be activated in PROD mode. The SolveWare category for this rule is 1—little or no customization is required before implementation.  | 
Parent Topic |