Select minor step 5 in the Minor Steps Selection screen and insert values for the SMP data sets parameters, as shown in the following table:
Note: When specifying values for parameters or subparameters that include both unit and volume (volser) fields, you must either define both fields, or leave both of them blank. Do not enter a value for only one of them.
Table 12 SMP data sets parameters
Parameter  | 
Description  | 
|---|---|
SPDPREF  | 
High level data set name qualifiers of the SMP/E Distribution libraries. 
  | 
SPDUNIT  | 
Unit of the disk on which the SMP/E Distribution libraries are to be placed. Specify a generic unit (for example, 3390—not SYSDA). 
  | 
SPDVOL  | 
Serial number of the volume on which SMP/E distribution libraries are to be placed. 
  | 
SPAPREF  | 
High level data set name qualifiers (prefix) of the SMP/E Auxiliary data sets, that is, SMPPTS, SMPMTS, SMPSTS, SMPLTS, SMPSCDS. 
  | 
SPAUNIT  | 
Unit of the disk on which the SMP/E Auxiliary (SMPPTS, SMPMTS, and so on) data sets are to be placed. Specify a generic unit (for example, 3390—not SYSDA). 
  | 
SPAVOL  | 
Serial number of the volume on which the SMP/E Auxiliary data sets (SMPPTS, SMPMTS, and so on) are to be placed. 
  | 
LEPREF  | 
IBM Language Environment library prefix in the system where the maintenance will be run. 
 The presence of the following libraries is mandatory: 
  | 
IBMCPREF  | 
IBM XML C/C++ library prefix in the system where the maintenance will be run. 
 The presence of the following library is mandatory: 
  | 
ICSFPREF  | 
The IBM Integrated Cryptographic Services Facility library prefix in the system where maintenance will be run. 
 The presence of the IBM ICSF load library is mandatory: 
  | 
Parent Topic |