Control-M/Server Installation
If you have additional load balancing and geo-redundancy requirements, you can install multiple instances of Control-M/Server.
Before you install Control-M/Server, verify the requirements, as described in Control-M/Server System Requirements.
If you are installing Control-M/Server on UNIX, complete the pre-installation procedures, as described in Control-M/Server Pre-installation Procedures on UNIX, and the post-installation procedures, as described in Post-installation Procedures on UNIX.
You can install Control-M/Server with one of the following options:
-
Default: Installs Control-M/Server with a dedicated BMC-supplied PostgreSQL database server, default database name, default username and default ports.
-
Custom: Enables you to select a database server, database name, username and ports.
The Control-M/Server installation includes a local installation of Control-M/Agent, which is critical to the functionality of Control-M/Server. To avoid potential corruption to the product, do not uninstall, disable, or delete this Agent.
-
If you are installing Control-M/Server with a PostgreSQL database on the same host where Control-M/EM with a PostgreSQL database was installed, you must use a different port for the second database instance.
-
If you are installing Control-M/EM and Control-M/Server on the same host or installing multiple instances of Control-M/Server on the same host (UNIX only), you must configure the Zookeeper and Kafka services to use different ports on Control-M/EM and on the additional Control-M/Server instances, as described in KA 000374213.
-
If you are installing Control-M/EM and Control-M/Server on the same Windows host, BMC recommends that you install them on the same home directory to avoid multiple Kafka installations.
The following procedures describe how to install Control-M /Server on UNIX and Windows via an interactive or automatic installation:
Control-M/Server System Requirements
Before you install Control-M/Server, verify that your operating system, processor, and database server are supported and have the correct amount of memory and disk space. For a full list of requirements, see the Control-M 9.0.02 Release Notes.
Verify that your system meets one of the following requirements:
The number of processes limit must be equal to or greater than the number of expected parallel running jobs.
Control-M/Server UNIX System Requirements
The following table lists the prerequisite requirements for a UNIX platform.
These values represent the minimum requirements for an entry level deployment. For higher capacity workloads, add resources.
|
Resource |
Specification |
Requirement |
|---|---|---|
|
Compatible Processors |
||
|
Linux |
x86_64 |
|
|
Memory |
N/A |
Depends on the size of your production environment:
For more information about these sizes, see Control-M/Server Production Size. You need an additional 4 GB if the database is on the same host as Control-M/Server. |
|
Disk Space |
N/A |
40 GB Upgrade: 7 GB If you are installing Control-M with a remote database server, you must have 5 GB free on the database server. BMC Software recommends that you reserve 1.5 times the amount of RAM in the system for swap space. |
|
CPU |
4 vCPU |
100 SPEC rating (2006_int_rate) |
|
Database |
N/A |
Control-M/Server Windows System Requirements
The following table lists the prerequisite requirements for a Windows platform.
These values represent the minimum requirements for an entry level deployment. For higher capacity workloads, add resources.
|
Resource |
Requirement |
|---|---|
|
CPU |
4 vCPU 100 SPEC rating (2006_int_rate) |
|
Compatible Processors |
x86_64 processors:
|
|
Display |
16-bit (65,536) colors or higher |
|
Memory |
Depends on the size of your production environment:
For more information about these sizes, see Control-M/Server Production Size. You need an additional 4 GB if the database is on the same host as Control-M/Server. |
|
Disk Space |
40 GB Upgrade: 7 GB If you are installing Control-M with a remote database server, you must have 5 GB free on the database server. BMC Software recommends that you reserve 1.5 times the amount of RAM in the system for swap space. |
|
Database |
Control-M/Server Production Size
The following table summarizes the criteria that determine production environment size categories.
| Measurement |
Small |
Medium |
Large |
|---|---|---|---|
|
Active jobs |
0–15,000 |
14,000–75,000 |
70,000–150,000 |
|
Job executions per day |
0–15,000 |
14,000–75,000 |
70,000–150,000 |
Control-M/Server Pre-installation Procedures on UNIX
Before you install Control-M/Server, you need to complete the following procedures:
-
Configuring a User Account on UNIX: Describes how to configure specific parameters for Control-M/Server.
-
Setting Environment Variables in UNIX: Describes how to set environment variables in UNIX, which enables you to see messages from the console.
-
PostgreSQL UNIX Kernel Parameters: Describes how to modify AIX and Linux system parameters, which enables you to allocate resources for Control-M components.
-
Setting the Java Environment Variable: Describes how to set the Java environment variable, which points to an external Java installation.
-
Verifying Operating System Levels and Patches: Describes how to verify operating system level and patches with Control-M/Server requirements.
Installing Control-M/Server on UNIX
This procedure describes how to install Control-M/Server on UNIX. You can automatically or interactively install Control-M with its default settings or custom define its database server and name, along with the component usernames, hostnames, and port settings.
Before You Begin
-
Complete all Pre-installation Procedures.
-
Verify that you meet the system requirements, as described in Control-M/Server UNIX System Requirements.
-
Verify that an external Java package is installed, as described in External Java Installation.
-
Download the installation package, as described in Obtaining Control-M Installation Files.
-
(Cluster configurations only) Configure Control-M/Server in a cluster environment, as described in Cluster Configuration.
Begin
-
Copy the installation files from the temporary directory that you created in Obtaining Control-M installation files, to the home directory.
-
Set your DISPLAY environment variable, as described in Setting Environment Variables in UNIX.
-
From your home directory, run the following command:
<source_path>/setup.sh
-
Do one of the following:
-
Interactive Installation: Select the Control-M/Server option and continue with the on-screen instructions until the installation is complete.
-
Automatic Installation: Create a parameter file and then run the automatic install in a non-interactive mode, as follows:
-
Select the Control-M/Server option and continue with the on-screen instructions until the Summary window.
-
Click Generate and select the location where the XML parameter file is created.
-
Click Yes to quit the installation.
A confirmation message appears.
-
Click Yes.
-
Copy the automatic installation parameters file to a network location that is accessible to all hosts where you want to perform an automatic installation.
-
To run the installation script, run the following command:
<source_path>/Setup_files/components/ctm/setup.sh -silent <xml_path>/<filename.xml>
If you want to encrypt a password in the installation, run the following command:
<source_path>/Setup_files/components/ctm/setup.sh -encrypt <password>
The installation log can be found at the following location:
<$HOME>/BMCINSTALL/log/BMC_Control-M_Server_<date-time>.log
The backup file is available in the following location:
$HOME/BMCINSTALL/uninstall/DRCTV.9.0.02/backup_area
-
-
-
Continue with Automatic Startup/Shutdown Procedure for Control-M/Server on UNIX.
If you installed Control-M/Server on NFS, you can only use the Control-M/Server user on the same host where Control-M/Server was installed.
-
If a firewall is active, perform the steps described in System Configuration.
Installing a Control-M/Server Fix Pack on UNIX
This procedure describes how to install a Control-M/Server fix pack on UNIX.
-
You must install this patch on every host where Control-M/Server is installed.
-
In a High Availability environment, you must install this fix pack on active and non-active hosts.
Before You Begin
-
Ensure that you have already installed Fix Pack PAOST.9.0.22.100, as indicated in the <CTM_Home>/installed_versions.txt file or (in a Control-M Full Installation) the <HOME>/installed_versions.txt file.
-
Verify that Control-M/Server 9.0.02 is installed before you install this fix pack.
Begin
-
Log in to the account where Control-M/Server is installed and copy the installation files from the temporary directory that you created in Obtaining Control-M installation files, to a temporary directory on your local hard drive (not a network drive).
-
Extract the package with the following command:
unzip PACTV.9.0.21.000.zip
-
In a High Availability environment, stop the Control-M/Server Configuration Agent on the non-active environment to avoid automatic failover.
-
Navigate to the following directory:
<Extracted_Directory>/PACTV.9.0.21.000
-
Do one of the following:
-
Interactive Installation: Run the following command:
./install_patch.sh
-
Automatic Installation: Run the following command:
./install_patch.sh -s
-
-
Follow the on-screen instructions until the installation is complete.
The installation file shuts down the Control-M/Server components, installs the patch, and restarts the components.
-
In a High Availability environment, do the following:
-
Verify that the Control-M/Server Configuration Agent on the non-active environment is up after the installation completes.
-
Repeat the entire procedure on the non-active environment.
-
Installing Control-M/Server on Windows
This procedure describes how to install Control-M/Server on Windows. You can automatically or interactively install Control-M with its default settings or custom define its database server and name, along with the component usernames, hostnames, and port settings.
-
If Control-M/EM and Control-M/Server are installed on the same Windows host (including a cluster), they must be installed on the same drive.
-
BMC recommends that you extract the installation files with a third-party extraction tool, such as WinZip, 7-Zip, or NanoZip, to avoid the 260-character extraction limit of the Windows built-in extraction utility
Before You Begin
-
Verify that you meet the system requirements, as described in Control-M/Server Windows System Requirements.
-
Verify that an external Java package is installed, as described in External Java Installation.
-
Download the installation package, as described in Obtaining Control-M Installation Files.
Begin
-
Log in to the host using a user ID that has Administrator permissions.
-
Copy the installation files from the temporary directory that you created in Obtaining Control-M installation files, to the home directory.
-
From a command prompt window, run the following command:
<source_path>\setup.exe
-
Do one of the following:
-
Interactive Installation: Select the Control-M/Server option and continue with the on-screen instructions until the installation is complete.
-
Automatic Installation: Create a parameter file and then run the automatic install in a non-interactive mode, as follows:
-
Select the Control-M/Server option and continue with the on-screen instructions until the Summary window.
-
Click Generate and select the location to create the XML parameter file.
-
Click Yes to quit the installation.
A confirmation message appears.
-
Click Yes.
-
Copy the automatic installation parameters file to a network location that is accessible to all hosts where you want to perform an automatic installation.
-
Log in using a user ID that has Administrator permissions on the current host.
Run the following installation script:
<source_path>\Setup_files\components\ctm\setup.exe -silent <xml_path>\<filename.xml>
If you want to encrypt a password in the installation, run the following command:
<source_path>\Setup_files\components\ctm\setup.exe -encrypt <password>
The installation log can be found at the following location:
<installFolder>\BMCINSTALL\log\BMC_Control-M_Server_<date-time>.log
The backup file is available in the following location:
<Install Directory>\BMCINSTALL\uninstall\DRCTV.9.0.02\backup_area
-
-
-
If a firewall is active, perform the steps described in System Configuration.
Installing a Control-M/Server Fix Pack on Windows
This procedure describes how to install a Control-M/Server fix pack on Windows.
-
You must install this patch on every host where Control-M/Server is installed.
-
In a High Availability environment, you must install this fix pack on active and non-active hosts.
Before You Begin
-
Ensure that you have already installed Fix Pack PAOST.9.0.22.100, as indicated in the <CTM_Home>\installed_versions.txt file or (in a Control-M Full Installation) the <HOME>\installed_versions.txt file.
-
Verify that Control-M/Server 9.0.02 is installed before you install this fix pack.
-
(Control-M cluster configurations only) From the Roles section in the Cluster Manager, shut down the following processes:
-
Control-M/Server Configuration Agent
-
Control-M/Server
-
Kafka for Control-M/Server
-
ZK for Control-M/Server
-
Begin
-
Log in to the account where Control-M/Server is installed and copy the installation files from the temporary directory that you created in Obtaining Control-M installation files, to a temporary directory on your local hard drive (not a network drive), and then extract the package to c:\temp.
-
In a High Availability environment, stop the Control-M/Server Configuration Agent on the non-active environment to avoid automatic failover.
-
Navigate to the following directory:
c:\temp\PACTV.9.0.21.000
-
Do one of the following:
-
Interactive Installation: Run the following command:
install_patch.bat
-
Automatic Installation: Run the following command:
install_patch.bat -s
-
-
Follow the on-screen instructions until the installation is complete.
The installation file shuts down the Control-M/Server components, installs the patch, and restarts the components.
-
In a High Availability environment, do the following:
-
Verify that the Control-M/Server Configuration Agent on the non-active environment is up after the installation completes.
-
Repeat the entire procedure on the non-active environment.
-
-
(Control-M cluster configurations only) From the Roles section in the Cluster Manager, start up the following processes:
-
Control-M/Server Configuration Agent
-
Control-M/Server
-
Kafka for Control-M/Server
-
ZK for Control-M/Server
-
Uninstalling Control-M/Server from UNIX
This procedure describes how to uninstall Control-M/Server from UNIX.
Before You Begin
Ensure that all jobs have ended.
Begin
-
Log in as a Control-M/Server user.
-
Navigate to the following directory:
<ctmserver_InstallFolder>/BMCINSTALL/uninstall/
-
Do one of the following:
-
Interactively Uninstall: Run the following command:
DRCTV.9.0.02/uninstall.sh
-
Automatically Uninstall: Run the following command:
DRCTV.9.0.02/uninstall.sh -silent
Control-M/Server is successfully removed from your host. If you downgraded, Control-M components are up and running.
-
Uninstalling a Control-M/Server Fix Pack from UNIX
This procedure describes how to uninstall a Control-M/Server fix pack from UNIX.
In a High Availability environment, you must uninstall the fix pack from active and non-active hosts.
Begin
-
Log in to the account where Control-M/Server is installed.
-
In a High Availability environment, stop the Control-M/Server Configuration Agent on the non-active environment to avoid automatic failover.
-
Navigate to the following directory:
<Control-M/Server_Home>/patches/PACTV.9.0.21.000
-
Run the following command:
./uninstall_patch.sh
The uninstall file shuts down your Control-M/Server components, uninstalls the patch, and restarts the components.
-
In a High Availability environment, run the following command on the non-active environment:
./uninstall_patch.sh
The uninstall file shuts down your Control-M/Server components, uninstalls the fix pack, and restarts the components.
-
Verify that the Control-M/Server Configuration Agent on the non-active environment is up after the uninstallation completes.
Uninstalling Control-M/Server from Windows
This procedure describes how to uninstall Control-M/Server from Windows.
Before You Begin
-
Ensure that all jobs have ended.
Begin
-
From the Start menu, select Control Panel.
-
Double-click Programs and Features.
-
Select Control-M/Server 9.0.02, and click Uninstall.
-
Click OK to continue.
Control-M/Server is successfully removed from your host. If you downgraded, Control-M components are up and running.
Uninstalling a Control-M/Server Fix Pack from Windows
This procedure describes how to uninstall a Control-M/Server fix pack from Windows.
In a High Availability environment, you must uninstall the fix pack from active and non-active hosts.
Before You Begin
-
Ensure that all jobs have ended.
-
(Control-M cluster configurations only) From the Roles section in the Cluster Manager, shut down the following processes:
-
Control-M/Server Configuration Agent
-
Control-M/Server
-
Kafka for Control-M/Server
-
ZK for Control-M/Server
-
Begin
-
Log in to the account where Control-M/Server is installed.
-
In a High Availability environment, stop the Control-M/Server Configuration Agent on the non-active environment to avoid automatic failover.
-
Navigate to the following directory:
<Control-M/Server_Home>\patches\PACTV.9.0.21.000
-
Run the following command:
uninstall_patch.bat
The uninstall file shuts down your Control-M/Server components, uninstalls the fix pack, and restarts the components.
-
In a High Availability environment, run the following command on the non-active environment:
uninstall_patch.bat
The uninstall file shuts down your Control-M/Server components, uninstalls the fix pack, and restarts the components.
-
(Control-M cluster configurations only) From the Roles section in the Cluster Manager, start up the following processes:
-
Control-M/Server Configuration Agent
-
Control-M/Server
-
Kafka for Control-M/Server
-
ZK for Control-M/Server
-
-
Verify that the Control-M/Server Configuration Agent on the non-active environment is up after the uninstallation completes.
Performing an Automatic Control-M/Server Uninstall on Windows
This procedure describes how to uninstall Control-M/Server from Windows via an automatic uninstall.
Before You Begin
Ensure that all jobs have ended.
Begin
-
Log in to the host using a user ID that has Administrator permissions.
-
Navigate to the following directory:
<ctmserver_InstallFolder>\BMCINSTALL\uninstall\DRCTV.9.0.02
-
Run the following command:
Uninstall.exe -silent
Control-M/Server is successfully removed from your host.
Configuring the Automatic Startup/Shutdown Procedure for Control-M/Server on UNIX
This procedure describes how to configure the automatic startup procedure for Control-M/Server on Red Hat 8 and 9, Oracle Linux 7, and SUSE Linux Enterprise Server 12. You must perform this procedure after you install Control-M/Server.
If you installed Control-M/Server on NFS, you can only use the Control-M/Server user on the same host where Control-M/Server was installed.
Begin
-
Log in as root.
-
Navigate to the following location:
/etc/systemd/system/
-
Create a new unit service file with 644 permissions.
The extension must be .service.
EXAMPLE: CtmServer.service
-
Open the file and type the following:
Copy[Unit]
Description=Control-M Server
After=systemd-user-sessions.service multi-user.target network.target
[Service]
ExecStart=/bin/sh -c [server_home_dir]/ctm_server/data/rc.<account name>
Type=forking
RemainAfterExit=yes
ExecStop=/usr/bin/su - <account name> -c '[server_home_dir]/ctm_server/scripts/shut_ca ; [server_home_dir]/ctm_server/scripts/shut_ctm -CA; sleep 10 ; [server_home_dir]/ctm_server/scripts/shutdb; [server_home_dir]/ctm_server/scripts/shut_kafka'
[Install]
WantedBy=multi-user.target -
Save the file.
-
From a command line, run the following commands:
-
systemctl daemon-reload
-
systemctl enable [unit service file].service
-
-
Restart the Control-M/Server host.